Product description:
Frequently Asked Questions
What refrigerant is used in this air conditioner?
This air conditioner uses R32 refrigerant, which is a fluorinated greenhouse gas covered by the Kyoto Protocol. It is important to handle and dispose of this refrigerant properly to avoid environmental harm.
What safety precautions should be taken during installation?
Installation must be performed by qualified personnel only. Ensure the unit is installed in a well-ventilated area, away from flammable materials and open flames. Use a dedicated power supply circuit and ensure proper grounding to prevent electric shocks. Avoid using tapped wires or extension leads to prevent overheating and fire hazards.
How should the refrigerant circuit be handled during installation?
During installation or relocation, bleed the refrigerant circuit to remove air and use only the specified refrigerant (R32). Ensure the refrigerant charge is correct and check for leaks after installation. If a leak is detected, ventilate the area immediately and contact a qualified technician.
What are the requirements for the installation room?
The room must have a floor area larger than 3m² and be well-ventilated. Ensure the room has no continuous ignition sources within a radius of 2.5m. Avoid installing the unit near high-temperature sources or flammable materials to prevent fire hazards.
What should be done if refrigerant leaks during installation?
If a refrigerant leak is detected during installation, immediately close the outdoor unit valve, open windows for ventilation, and evacuate all personnel. Do not attempt to repair the leak yourself; contact a qualified technician to handle the refrigerant and ensure the area is safe.
What are the requirements for electrical wiring?
Use a dedicated power supply circuit and ensure the wiring is in line with local electrical standards. The type of connecting wire must be H07RN-F. All cables must have a European authentication certificate. Ensure proper grounding and avoid using tapped wires or extension leads.
The minimum room area required depends on the model and the refrigerant charge. For example, a unit with a refrigerant charge of 1.0kg requires a minimum room area of 19m². Refer to the installation manual for specific requirements based on the unit model.
What should be done with the unit after it is discarded?
Do not discard the air conditioner randomly. Contact Haier customer service to obtain the correct disposal methods. The unit must be disposed of at a specialized treatment facility to ensure proper recycling, recovery, and safe handling of the refrigerant and other components.
What are the requirements for the installation site?
The installation site must be free from flammable materials and open flames. Ensure the area is well-ventilated and avoid installing the unit near high-temperature sources. The unit must be installed in a location that is convenient for maintenance and not adjacent to flammable or combustible materials.
What should be done if the unit is damaged during installation?
If the unit is damaged during installation, it must be delivered to the maintenance department. Do not attempt to repair or weld refrigerant pipelines at the user’s site. Only qualified personnel should handle refrigerant-related repairs to ensure safety and compliance with regulations.
Related products from Haier
AS20S2SF2FA
User manual 130 pages
AS25S2SF2FA
User manual 130 pages
AS35S2SF2FA
User manual 130 pages
AS50S2SF2FA
User manual 130 pages
AS71S2SF2FA
User manual 130 pages
AS20TADHRA
User manual 130 pages
AS20TADHRA
User manual 130 pages
AS20TADHRA
User manual 130 pages
AS20TADHRA
User manual 142 pages
AS25TADHRA
User manual 130 pages
AS25TADHRA
User manual 130 pages
AS25TADHRA
User manual 130 pages
AS25TADHRA
User manual 142 pages
AS35TADHRA
User manual 130 pages
AS35TADHRA
User manual 130 pages
AS35TADHRA
User manual 130 pages
AS35TADHRA
User manual 142 pages
AS50TDDHRA
User manual 130 pages
AS50TDDHRA
User manual 130 pages
AS50TDDHRA
User manual 130 pages