Abus Terxon MX (82 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to fully activate the alarm system?
To fully activate the alarm system, ensure all zones are closed and enter a valid user code. The system will start a delay period, during which a continuous signal tone is emitted. After the delay, the system will activate if all zones are closed. If any zone remains open, the system will not activate and display the affected zones.
What are the different activation modes?
The alarm system can be activated in three modes: 'Exit Delay' (system activates after a set delay), 'Last Door' (system activates when the last zone is closed), and 'Manual' (system activates when a contact connected to the control panel is closed). Each mode has specific behavior and delay times.
What happens if a zone is open during activation?
If a zone is open during activation, the system will emit a double tone and display the affected zones. The system will not activate until all zones are closed. If the delay period expires and a zone is still open, an internal alarm will occur, and the system will not activate.
How to deactivate the alarm system?
To deactivate the alarm system, enter a valid user code within the set delay time after entering the premises through an entry/exit zone. If the code is not entered in time, the system will trigger an alarm. After deactivation, the system will emit a double tone and display the current date and time.
How to reset the alarm after an incident?
To reset the alarm after an incident, enter a valid user code. If the system was in an internal alarm state, a reset code may also be required. The system will display the affected zone and emit a double tone once the reset is successful.
What are the safety precautions for installation?
Ensure the system is installed in a dry location, away from moisture and extreme temperatures. Avoid connecting metallic objects to the system. Always work on the system when it is disconnected from power. Use only the correct fuse types and ensure proper ventilation for the central unit.
How to activate the system internally?
To activate the system internally, use the control panel and enter a valid user code. The system will start a delay period, during which a continuous signal tone is emitted. The internal activation mode allows monitoring specific zones or areas, depending on the system's programming.
What is the purpose of the control panel?
The control panel allows users to activate, deactivate, and manage the alarm system. It includes functions such as zone locking, user code management, event logging, and system testing. The panel also provides visual and auditory feedback for system status and alarms.
How to use the key switch for activation?
A key switch allows activation or deactivation of the alarm system without a user code. The system can be activated in different zones depending on the key switch programming. The system will emit a confirmation tone upon successful activation or deactivation.
What are the system requirements for operation?
The system requires a 230V AC power supply and operates on a 12V DC transformer. It is designed for indoor use only and must be installed in a dry environment with proper ventilation. The maximum ambient temperature should not exceed 55°C, and the humidity should not exceed 90% (non-condensing).
Related products from Abus
Smartvest FUBE35001A
User manual 2 pages
FUEM35000A
User manual 4 pages
SECVEST
User manual 52 pages
Smartvest FUAA35010A
User manual 4 pages
Secvest 2WAY
User manual 29 pages
Secvest 2WAY
User manual 32 pages
Secvest 2WAY
User manual 220 pages
Terxon LX
User manual 38 pages
CASA10010
User manual 123 pages
CITADEL Micral
User manual 68 pages
Terxon
User manual 189 pages
Terxon
User manual 245 pages