Product description:
Frequently Asked Questions
How do I activate Blue Connect?
To activate Blue Connect, open the Blueriiot app, go to 'Settings' > 'My Blue Connect', and press 'Add a Blue Connect'. Scan the QR code on the storage cap or enter the code and serial number. Shake the device to start activation, and press 'ok' to finalize. The device will then connect to your account and the Sigfox network.
What parameters does Blue Connect measure?
Blue Connect measures water temperature (in °C or °F), pH level, ORP/REDOX (active chlorine in mV), and conductivity (in μS). These measurements help assess water quality and ensure proper disinfection and balance.
How do I install Blue Connect in the water?
Place Blue Connect upright in the water, ensuring the top part is out of the water for proper communication. Secure it with the cord and rubber ring if needed, or use Blue Fit50 in the technical room. Always use the usage cap to protect the sensors.
What should I do if there is no Sigfox coverage?
If Sigfox coverage is unavailable, Blue Connect can use Bluetooth® for manual measurements, or you can use Blue Extender to connect to your Wi-Fi network. Both options require manual input to ensure accurate data collection.
How do I store Blue Connect when not in use?
When not in use, store Blue Connect vertically in a sheltered location. Keep the storage cap filled with KCl or pH4 to protect the probe. Ensure the probe is never left dry and rinse it with clear water before use.
What is the purpose of the storage cap?
The storage cap is used to protect the probe when transporting or storing Blue Connect. It contains KCl or pH4 to maintain the probe's condition. Always use the storage cap when removing the device from water.
How do I calibrate Blue Connect?
Calibration is handled automatically by the device. Ensure the probe is immersed in water and the storage cap is properly sealed. If manual calibration is required, follow the instructions in the app or refer to the user manual for detailed steps.
What is the role of the usage cap?
The usage cap must be mounted on the device before submerging it in water. It protects the sensors from damage and ensures accurate readings. Always use the usage cap to prevent exposure of the probe to air.
Can Blue Connect work with Bluetooth only?
Blue Connect can operate with Bluetooth® if Sigfox coverage is unavailable. However, manual measurements must be taken nearby and entered daily for the device to function as an analyzer. This is not recommended for long-term use.
What is the difference between conductivity and salinity?
Conductivity measures the concentration of inorganic salts in the water based on electrical conductivity. Salinity, specifically for salt pools, is an estimate of total dissolved solids (TDS) in grams per liter. Conductivity is measured by Blue Connect Plus, while salinity is an estimated value based on conductivity.