Dräger Pac 5500 (99 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the purpose of the Dräger Pac 3500/5500?
The Dräger Pac 3500/5500 is designed to measure carbon monoxide (CO), hydrogen sulfide (H2S), and oxygen (O2) concentrations in ambient air and initiate alarms at preset thresholds.
What are the alarm thresholds for CO, H2S, and O2?
The alarm thresholds are 30 ppm for CO, 5 ppm for H2S, and 19 vol.-% for O2. These thresholds are non-quittable and self-holding.
How long does the battery last under normal conditions?
The battery life is typically over 2 years for CO and H2S, and over 12 months for O2, assuming 8 hours of daily use and 1 minute of daily alarm operation at 25°C.
What is the operating temperature range for the device?
The operating temperature range is from -30°C to 50°C (-22°F to 122°F). The storage temperature range is from 0°C to 40°C (32°F to 104°F).
What is the alarm sound intensity?
The alarm sound intensity is typically 90 dB(A) at a distance of 30 cm (11.8 in.).
What are the environmental conditions for the device?
The device operates within environmental conditions of -30°C to 50°C, 700 to 1300 hPa pressure, and 10 to 90% relative humidity. The storage conditions are 0°C to 40°C and 30 to 80% relative humidity.
What is the IP rating of the device?
The device has an IP66 ingress protection rating, which means it is dust-tight and protected against water jets.
How do you replace the battery?
To replace the battery, turn off the device, remove the four screws from the back case, open the front case, remove the old battery, insert the new battery with correct polarity, and secure the case with the four screws.
What should you do if the device is not calibrating?
If the device is not calibrating, check the settings and recalibrate the instrument. If the issue persists, contact Dräger for further assistance.
What are the sensor specifications for CO, H2S, and O2?
The zero point for CO is ≤ ±2 ppm, for H2S ≤ ±0.1 ppm, and for O2 ≤ ±0.2 vol.-%. The sensitivity for CO is ≤ ±2% of the measured value, for H2S ≤ ±5%, and for O2 ≤ ±1% of the measured value.
Related products from Dräger
X-am 7000
User manual 56 pages
X-am 7000
User manual 64 pages
X-am 7000
User manual 120 pages
X-am 2500
User manual 248 pages
X-am 2500
User manual 328 pages
X-am 2500
User manual 352 pages
X-am 2500
User manual 400 pages
X-am 2500
User manual 420 pages
X-am 5600
User manual 396 pages
Polytron 8900 UGLD
User manual 2 pages
Polytron 8900 UGLD
User manual 122 pages
Polytron 2000
User manual 8 pages
Polytron 2000
User manual 32 pages
X-zone 5000
User manual 8 pages
Pac 3500
User manual 99 pages
X-am 3500
User manual 194 pages
X-am 3500
User manual 196 pages
DrugTest 5000
User manual 22 pages
DrugTest 5000
User manual 30 pages
DrugTest 5000
User manual 56 pages