GE Sievers 900 (16 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How does the GE Sievers 900 measure total organic carbon (TOC)?
The GE Sievers 900 converts organic carbon to carbon dioxide using UV-persulfate oxidation and quantifies the resulting CO2 with a non-dispersive infrared (NDIR) detector. This approach yields sensitive and selective TOC readings, and you should ensure oxidant quality and stable UV lamp output to maintain measurement accuracy.
What detection limits and sensitivity can I expect from this analyzer?
The instrument is designed for high sensitivity and can detect very low TOC concentrations depending on configuration and sample matrix, often in the low parts-per-billion range. To achieve minimum detection limits, minimize background contamination, use high-purity reagents, and perform regular blank and low-level standard checks.
Which types of water and environmental samples are compatible with the Sievers 900?
The Sievers 900 supports a wide range of matrices including drinking water, surface and ground water, wastewater, and pharmaceutical process waters. Different analysis modes accommodate varied matrices, but heavily particulate or viscous samples may require pretreatment such as filtration or dilution for reliable results.
How should samples be prepared before running a TOC analysis?
Typical preparation includes removing large particulates by filtration, diluting samples above the instrument range, and avoiding carbon-containing preservatives. Proper container rinsing and handling reduce contamination; follow laboratory sampling SOPs to ensure representativity and accurate TOC measurement.
How is the Sievers 900 calibrated and how often should calibrations be performed?
Calibration is performed with certified TOC standards using one- or multi-point routines, and frequency depends on usage and quality control requirements. Best practice is to run calibration checks and blanks at regular intervals, for example daily or per batch, and document results to detect drift early.
Which consumables and reagents does the instrument require for operation?
Essential consumables include the persulfate oxidant or equivalent reagents for UV-persulfate oxidation, replacement UV lamp(s), sample filters, and high-purity water for blanks and rinses. Using certified reagents and scheduled replacement of lamp and tubing helps maintain reproducibility and low background.
What routine maintenance is necessary to keep the analyzer performing reliably?
Routine maintenance includes replacing the UV lamp and reagents per manufacturer intervals, inspecting and replacing worn tubing or seals, cleaning sample paths and filters, and performing periodic calibration and diagnostic checks. A preventive maintenance schedule and logbook reduce downtime and maintain data quality.
How does the automated sample handling affect throughput and reproducibility?
Automated sample handling increases throughput by running sequences unattended and improves reproducibility through consistent injection timing and volume control. Throughput depends on selected analysis mode and sample concentration; grouping similar matrices and optimizing run parameters maximizes efficiency.
What data logging and connectivity features does the Sievers 900 offer?
The analyzer supports internal data logging and common digital interfaces for exporting results and integrating with laboratory data systems. Exportable data formats and network connectivity allow centralized record keeping and LIMS integration; ensure proper backup and secure data handling to meet QA requirements.
What common problems cause unstable TOC readings and how can I troubleshoot them?
Unstable readings often stem from contaminated reagents, degraded UV lamp intensity, blocked sample lines, improper calibration, or sample matrix interferences. Troubleshoot by running blanks and standards, inspecting reagent quality and tubing, checking lamp status, and repeating calibration to isolate and resolve the source.