Hach ORBISPHERE 3100 (414 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the measurement range of the ORBISPHERE 3100 analyzer?
The ORBISPHERE 3100 analyzer has a measurement range of 0 to 2000 ppb for oxygen concentration. This range allows for accurate detection of oxygen levels in various gaseous or liquid samples.
What are the operating temperature and humidity conditions for the analyzer?
The analyzer operates within an ambient temperature range of -5 to 45°C (23 to 113°F) and a relative humidity of 0 to 95% non-condensing for temperatures below 30°C (86°F). For temperatures between 30 to 45°C (86 to 113°F), the humidity should be 0 to 70% non-condensing.
What is the battery life and charging time for the ORBISPHERE 3100?
The battery provides more than 10 hours of continuous measurement. Charging time is less than 4 hours. However, charging time increases by 20% at temperatures above 35°C (95°F). The battery should not be used or stored in high-temperature environments to avoid damage.
What are the safety precautions for using the ORBISPHERE 3100 analyzer?
The analyzer uses a lithium battery, and users must avoid exposing the battery to extreme temperatures, liquids, or fire. If the battery emits an unusual smell, smoke, or becomes unusually hot, the instrument should be stopped immediately and the user should contact Hach Service Center. The battery should never be placed in microwave ovens, high-pressure containers, or near heat sources.
How do you connect the sample lines to the ORBISPHERE 3100 analyzer?
The sample inlet and outlet connections are located on the ON/OFF sample flow valve. The inlet tubing should be connected to the sample source, and the outlet tubing to the drain. The sample flow valve can be adjusted to control the flow rate, and the PURGE position can be used to clear air bubbles from the sample line.
What are the recommended flow rates for the sample lines?
For cans and bottles, the minimum recommended flow rate is 150mL/min. For small volume packages, a lower flow rate can be used, but it should not be below 100mL/min. For tank and in-line applications, the flow rate should be above 200mL/min and up to the maximum allowed by the flow adjustment valve.
How do you install the 3100 PC software?
The PC software can be installed by inserting the USB key into your PC and running the setup program from the directory Orbisphere 3100\Installation Files\PC Software. The software will be installed on your hard disk in a new directory: C:\Program Files\Hach Lange\3100 PC Software\. Once installed, the application can be launched from the desktop icon.
What are the safety symbols on the ORBISPHERE 3100 analyzer and their meanings?
The analyzer includes safety symbols indicating potential hazards such as electrical shock, electrocution, and electrostatic discharge (ESD). These symbols are used to warn users of risks and guide them on proper handling and disposal of the instrument. The symbols also indicate that the instrument is connected to alternating current and contains toxic or hazardous substances.
What is the maximum altitude the ORBISPHERE 3100 can operate at?
The ORBISPHERE 3100 analyzer can operate at a maximum altitude of 2000 meters (6562 feet). This ensures that the instrument functions correctly in various environmental conditions without performance degradation.
How do you reconnect the battery power to the ORBISPHERE 3100 analyzer?
To reconnect the battery power, tilt the instrument to reveal the screws holding the front panel in place. Remove the screws, lift off the front panel, and use a long-bladed flat-head screwdriver to turn the internal battery power switch a quarter turn clockwise. Replace the front panel and secure it with the screws. Always follow this procedure in reverse when preparing for transportation.
Related products from Hach
AV9000
User manual 164 pages
SL1000
User manual 476 pages
POCKET COLORIMETER II
User manual 116 pages
POCKET COLORIMETER II
User manual 118 pages
POCKET COLORIMETER II
User manual 132 pages
POCKET COLORIMETER II
User manual 152 pages
LCK 310
User manual 116 pages
ORBISPHERE 410
User manual 360 pages
ORBISPHERE 410
User manual 390 pages
ORBISPHERE 410
User manual 438 pages
ORBISPHERE 410
User manual 546 pages
ORBISPHERE 3655
User manual 122 pages
ORBISPHERE 3655/111
User manual 122 pages
Amtax SC
User manual 232 pages
LCK 360
User manual 132 pages
COD
User manual 152 pages
CSB
User manual 152 pages
DCO
User manual 152 pages
DQO
User manual 152 pages
LCK 014
User manual 152 pages