Product description:
Frequently Asked Questions
What is the operating temperature range for the analyzer?
The analyzer operates within a temperature range of –5 to 50°C (23 to 122 °F).
What is the maximum operating altitude for the analyzer?
The analyzer is rated for an altitude of up to 2,000 m (6,550 ft) above sea level.
What are the EMC requirements for the analyzer?
The analyzer meets the EMC requirements specified by EN61326-1: EMC Directive. It is classified as a Class A product, which may cause radio interference in domestic environments.
What is the power supply specification for the analyzer?
The analyzer uses a universal power supply of 100 VAC to 240 VAC @ 50/60 Hz - 40VA, or 10 to 30 VDC 30W.
What are the analog current output options for the analyzer?
The analyzer provides 4-20 mA (default) or 0-20 mA (configurable via software), with three configurable outputs. Each output has a maximum load of 500 ohms, sensitivity of 20μA, and an accuracy of ± 0.5%.
What are the analog voltage output options for the analyzer?
The analyzer provides 0-5 V output (hardware option) with three configurable outputs. Each output has a minimum load of 10 KOhm, sensitivity of 5 mV, and an accuracy of ± 0.5%.
What are the specifications for the K-M1100 sensors?
The K-M1100 sensors measure oxygen in liquid and gas phases. Low range sensors have a measurement range of 0 to 2000 ppb (dissolved) and 0 to 50 mbar or 0 to 5% O2 (at atm pressure). High range sensors have a measurement range of 0 to 40 ppm (dissolved) and 0 to 1 bar or 0 to 100% O2 (at atm pressure).
What is the response time for the K-M1100 sensors?
The response time for low range sensors is less than 30 seconds (90%), and for high range sensors, it is less than 50 seconds (90%).
What is the display resolution for the analyzer?
The display resolution for high range sensors is 0.001 mbar or 1 ppm gas, and for low range sensors, it is 0.1 ppb.
What safety precautions should be taken during installation?
During installation, ensure that the equipment is connected to a proper ground, avoid direct AC power connection to DC-powered instruments, and use a GFCI/GFI device if the equipment is used outdoors or in wet locations. Always disconnect power before making electrical connections.
Related products from Hach
AV9000
User manual 164 pages
DR 3900
User manual 15 pages
DR 3900
User manual 403 pages
DR 3900
User manual 446 pages
LANGE DR 1900
User manual 206 pages
2100Q
User manual 306 pages
2100Q
User manual 344 pages
LANGE 2100Qis
User manual 206 pages
LANGE 2100Qis
User manual 306 pages
LANGE 2100Qis
User manual 344 pages
BOD Direct plus
User manual 290 pages
SL1000
User manual 476 pages
LANGE LUMIStox 300
User manual 45 pages
POCKET COLORIMETER II
User manual 116 pages
POCKET COLORIMETER II
User manual 118 pages
POCKET COLORIMETER II
User manual 132 pages
POCKET COLORIMETER II
User manual 152 pages
LCK 310
User manual 116 pages
ORBISPHERE 410
User manual 360 pages
ORBISPHERE 410
User manual 390 pages