Product description:
Frequently Asked Questions
What safety precautions should be taken when installing the pH dosing system?
Always ensure the equipment is de-energized and locked out before starting any work. Only qualified personnel should handle the installation, and they must use personal protective equipment such as safety glasses and gloves. Avoid contact with moving parts and ensure the device is out of reach of children.
What should be done if the pH dosing system malfunctions?
Do not attempt to repair the system yourself. Contact a qualified technician immediately. The system should not be used if it is not functioning properly to avoid damage or injury.
What are the recommended water balance parameters for the pool?
Maintain a pH level between 7.2 and 7.4. Free chlorine should be between 0.5 and 2 mg/L, and total alkalinity (TAC) should be between 8 and 15 °f (80–150 ppm). Metal content should be below 30 mg/L, and cyanuric acid (stabilizer) should be within ±0 ppm.
How often should water balance tests be performed?
Test the water balance weekly for pH and free chlorine, monthly for total alkalinity and metal content, and quarterly for cyanuric acid and calcium hardness. Regular testing helps maintain optimal water conditions and prevents equipment damage.
What is the injection cycle pattern for the pH dosing system?
The injection cycle adjusts based on the pH level. For example, if the pH is ≥7.55, inject for 2 minutes and pause for 8 minutes. If the pH is ≥7.7, inject for 5 minutes and pause for 5 minutes. The injection duration increases as the pH moves closer to the set point, with adjustments made in 0.15 pH increments.
Where should the pH probe and injection point be installed?
The pH probe should be installed at least 30 cm before or after a bend in the piping, and at least 60 cm away from the injection point. The probe should be placed after the filter and before the heating system, and it must be positioned vertically or at a 45° angle to avoid incorrect readings.
What are the electrical connection requirements for the system?
Connect the device to a 230Vac power supply with a dedicated residual current device (RCD) of 30 mA. Ensure the power cable is properly connected and avoid using extension cords. Always disconnect the device before performing any maintenance or repairs.
What should be done if the pH probe is not measuring accurately?
Check the probe positioning and ensure it is not in contact with the pipe. Verify that the probe is installed after the filter and before the heating system. Clean the probe and calibrate it according to the manufacturer's instructions. If the issue persists, contact a qualified technician.
What is the maximum flow rate for the peristaltic pump?
The maximum flow rate for the peristaltic pump is 1.5 liters per hour. This ensures precise and rapid adjustment to the set pH level. The system uses a proportional injection cycle with a total cycle time of 10 minutes, adjusting the injection and pause times based on the current pH level.
What should be done if the system is exposed to water or moisture?
Do not operate the system if it is wet or if your hands are wet. Ensure all electrical connections are dry before proceeding with any operation. If the system has been exposed to water, inspect for damage and contact a qualified technician before using it again.