The AEG ETH 21 is an electric boiler designed for efficient water heating in residential and commercial settings. It features a compact design, making it suitable for installation in small spaces. The boiler operates with high energy efficiency, ensuring cost-effective and environmentally friendly heating. It includes a built-in temperature control system for precise regulation of the water temperature. The unit is equipped with safety mechanisms to prevent overheating and ensure stable operation. It is compatible with standard electrical systems and requires minimal maintenance. The AEG ETH 21 is ideal for applications where reliable and continuous hot water supply is essential.

Frequently Asked Questions

What is the purpose of the ETH electric boiler?

The ETH electric boiler is designed for heating rooms equipped with a water-based central heating system in both closed and open circuits. It can function as a primary heat source or as a supplementary heater when used with a fireplace, solar system, or heat pump. It is compatible with traditional radiators, underfloor heating, and forced-air systems. The series offers optimal power selection for the heated space, with standard models available in 13 kW, 15 kW, 18 kW, 21 kW, and 24 kW.

What are the key components of the boiler?

The boiler includes a copper tank with heating elements, an automatic air vent, a terminal strip, a contactor, a microprocessor controller, a pressure sensor, a circulation pump, an air vent for the pump, 3/4" connection fittings, and an opening for the power cable. These components work together to ensure efficient and safe operation.

How do I install the boiler?

The boiler must be mounted on a vertical wall. Connect it to the central heating system according to PN-91/B-02413 (closed systems). For closed systems, connect a 3-bar safety valve and a expansion tank, whose size depends on the amount of water in the system. For open systems, use an overflow tank. Install a sediment filter before the circulation pump to protect it from contaminants. Do not install any additional circulation pumps. Ensure both sealing plugs are removed before installation.

How do I start the boiler?

Before starting, check that the heating system is filled and properly vented. The pressure in a closed system should be between 1-1.5 Bar. The pressure status is indicated by two LED lights labeled 'CIŚNIENIE'. Once the system is pressurized and the maximum temperature is set using the controller's potentiometer, the boiler is ready to operate. The potentiometer can be set to prevent freezing or to control the temperature as needed.

What are the pressure indicators for the system?

The pressure status is indicated by two LED lights: left and right. The left LED pulses for low pressure (below 0.2 Bar), stays on for moderate pressure (0.2-0.5 Bar), and stays on for normal pressure (0.5-1.5 Bar). The right LED stays off for low pressure, pulses for high pressure (above 2.5 Bar), and stays on for normal pressure. These indicators help ensure the system is operating safely.

How does the boiler operate in different modes?

The boiler can operate in standalone mode or in conjunction with external temperature regulators. In standalone mode, the temperature is set manually using the controller. For optimal performance, it is recommended to use a PT-xx thermostat, which allows for weekly programming and precise temperature control. The boiler adjusts its power output based on the temperature difference between the set and actual temperatures, maintaining a stable temperature with a ±4°C hysteresis.

What safety features are included in the boiler?

The boiler includes several safety features to protect the device and the heating system. These include a temperature limit switch for the tank, a return water temperature limiter, pressure control, pump failure detection, frost protection, priority control, and a pump circuit protection. These features ensure safe and reliable operation under various conditions.

What are the technical specifications of the boiler?

The boiler's technical specifications include power ratings of 13 kW, 15 kW, 18 kW, 21 kW, and 24 kW, operating voltages of 380 V and 400 V, a frequency of 50 Hz, and a maximum current of 25 A to 40 A. The allowable pressure range is 1-1.5 Bar for closed systems and 1-1.5 Bar for open systems. The dimensions are 390 mm in height, 250 mm in width, and 215 mm in depth, with a weight of 8.5 kg.

How do I handle frost protection in the boiler?

The boiler is protected against freezing in its circuit. If the internal temperature drops below 7°C, the heating system activates until the temperature reaches 20°C. This can also be manually triggered by setting the potentiometer to the snowflake symbol. In this mode, external regulator signals are ignored, ensuring the system remains operational in cold conditions.

What is the warranty and environmental protection policy?

The warranty applies to devices purchased outside Germany, but it is only valid if the local subsidiary provides it. Devices purchased in countries where no subsidiary is a distributor are not covered by the warranty. Environmental protection policies require proper disposal of used electrical and electronic equipment, following local regulations for waste management and recycling.