Geba Tronic Cody Universal 1/3 (92 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I program the Mastercode on Cody Universal?
To program the Mastercode, first enter the 8-digit Mastercode using the keypad. Press the 'Enter' key to confirm. The device will emit a 2x long signal tone, indicating the new Mastercode is saved. This code is required for all programming operations.
What is the default Mastercode for Cody Universal?
The default Mastercode for Cody Universal is 12345678. It is pre-programmed at the factory and should be changed to a personal code for security purposes.
How many Passcodes can be stored on Cody Universal?
Cody Universal can store up to 50 different Passcodes across memory slots 00 to 49. Each Passcode can be assigned to a specific relay or gate, allowing different users to access different gates with unique codes.
What is the Tiptomatic feature on Cody Universal?
The Tiptomatic feature allows you to operate the gate within 60 seconds after entering a Passcode, using any key except the 'Enter' key, without re-entering the code. This feature can be interrupted at any time by pressing the 'Enter' key.
How does the lockout function work on Cody Universal?
If the wrong Passcode is entered, the Cody Universal locks out for 20 seconds, indicated by a triple signal tone. You can also program the device to increase the lockout time by 10 seconds after each failed attempt, up to a maximum of 60 seconds.
What is the default Passcode for Cody Universal?
The default Passcode for Cody Universal is 1234, stored in memory slot 00 for Relay 1. This can be overwritten with a personal Passcode during programming for enhanced security.
What are the technical specifications of Cody Universal?
Cody Universal operates on 20-28V AC/DC or 230-240V AC. The relay output can handle up to 250V AC at 5A. The maximum cable size is 1.5 mm², and the operating temperature range is from -20°C to +60°C.
How do I change the control time for relays on Cody Universal?
To adjust the control time, enter the Mastercode, then input a 3-digit time value between 001 and 255. Press 'Enter' to save. The time can be set individually for each relay or applied to all relays simultaneously.
How do I delete a Passcode from Cody Universal?
To delete a Passcode, enter the Mastercode, then press the 'Enter' key twice. Input the 2-digit memory slot number where the Passcode is stored. The device will emit a single signal tone, confirming the Passcode has been deleted from that slot.
What is the maximum number of relays supported by Cody Universal?
Cody Universal supports up to three relays, making it suitable for controlling multiple gates or similar devices with a single control unit. This allows for flexible configuration and management of different access points.