Product description:
Frequently Asked Questions
What is the purpose of the Flamco Flexcon P expansion vessel?
The Flamco Flexcon P absorbs volume changes in heating and cooling circuits by separating the water chamber from a pre-charged air side, maintaining stable system pressure and preventing overpressure, leaks and frequent relief-valve operation for more reliable operation.
How does the flexible diaphragm in the Flexcon P operate?
A flexible diaphragm separates the liquid and gas sections so thermal expansion compresses the pre-charged air instead of raising system pressure; this design reduces waterlogging risk and provides predictable pressure buffering across cycles.
What temperature and pressure ranges can the Flexcon P handle?
Depending on the model, the vessel typically operates up to about 100°C and handles working pressures up to 10 bar; choose a model with a rated temperature and pressure above your system's maximum operating conditions for safety.
What materials and surface protection are used to prevent corrosion?
The unit is made from durable steel with corrosion-resistant coatings to extend service life in hydronic systems; combined with correct water treatment, this reduces internal and external corrosion and maintains mechanical integrity.
How do I choose the correct capacity of Flexcon P for my system?
Select capacity based on total system water volume and expected thermal expansion percentage at maximum temperature; allow a margin for pressure stability and cycling frequency to ensure efficient pressure regulation.
Where is the best location to install a Flexcon P in a system?
Install the vessel in an accessible, frost-protected location close to the system circuit so it sees representative system pressure; orientation and mounting depend on model, and space should allow pressure checks and servicing.
What are the common signs that an expansion vessel needs service or replacement?
Frequent pressure drops, continuous relief valve activation, inability to maintain set pressure, audible water hammer, or a vessel that feels waterlogged indicate diaphragm failure, lost pre-charge or corrosion and likely replacement need.
How should the pre-charge pressure of the vessel be checked and set?
Check pre-charge with a pressure gauge at the service valve while the system is isolated and drained to the same reference as the static system pressure; set pre-charge close to the system's cold static pressure for correct operation.
Is the Flexcon P suitable for systems with glycol or other heat transfer fluids?
The vessel generally works with common heat-transfer fluids, but compatibility depends on diaphragm and coating materials and glycol concentration; verify material compatibility and maintain correct inhibitor concentrations to prevent degradation.
What routine maintenance keeps the Flexcon P reliable over time?
Perform periodic visual inspections, check and adjust pre-charge pressure, monitor system pressure behaviour, protect the vessel from freezing and corrosion, and treat system water to prevent scale and corrosion for long service life.