Biral A 12-2 (128 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What are the models covered in this manual?
This manual covers the Biral circulation pumps models A 12, A 13, A 14, A 15, A 16, A 401, A 500, AD 401, A 12 KW, A 13 KW, A 14 KW, A 15 KW, A 16 KW, A 401 KW, A 500 KW, AD 401 KW, AW 15, AW 16, AW 401, and their variants.
What are the compliance standards for these pumps?
These pumps comply with the following EU directives: Machinery (2006/42/EC) with standard EN 12100-1, Electrical Equipment within Voltage Limits (2006/95/EC) with standards EN 60335-1:2002 and EN 60335-2-51:2003, and Electromagnetic Compatibility (2004/108/EC) with standards EN 61000-6-2 and EN 61000-6-3.
What are the operating temperature and pressure limits?
The operating temperature for the pump series A... (heating systems) is between +15°C and 95°C, with a short-term maximum of 110°C. For the series A...KW (cooling, climate, and refrigeration systems), the temperature range is between -10°C and 95°C. For the series AW... (drinking water systems), the temperature range is +15°C to 85°C. The maximum operating pressure is 10 bar.
What are the installation requirements for the pump?
The pump should be installed after all welding and soldering work is completed. Ensure the pump housing is voltage-free, and avoid any water contact with the motor and electronics. The pump housing must be properly sealed to prevent leaks.
What is the minimum pressure requirement for proper operation?
The minimum pressure at the pump suction port is 0.10 bar for temperatures below 75°C, 0.55 bar for temperatures below 90°C, and 1.20 bar for temperatures below 110°C. These values are valid up to 500 meters above sea level, with an additional 0.01 bar per 100 meters of elevation.
What are the safety precautions for installation and maintenance?
Installation and maintenance must be carried out by authorized and qualified personnel. All safety devices and protective measures must be reinstalled after work is completed. The pump must not be used for hazardous fluids, and the pump housing must be properly sealed to prevent water ingress.
What are the fluid requirements for the pump?
The pump is designed for clean, non-explosive, and thin liquids without solid or long-fiber particles. For heating systems, the fluid should be standard heating water with a maximum glycol content of 50%. For drinking water systems, the water hardness should not exceed 35 °fH (20 °dH) at temperatures below 65°C or 25 °fH (14 °dH) at temperatures below 85°C.
Related products from Biral
A 12
User manual 112 pages
A 12
User manual 128 pages
A 12
User manual 44 pages
A 14
User manual 44 pages
A 14
User manual 112 pages
A 14
User manual 128 pages
A 15
User manual 44 pages
A 15
User manual 112 pages
A 15
User manual 128 pages
A 16
User manual 112 pages
A 16
User manual 44 pages
A 13
User manual 44 pages
A 13
User manual 112 pages
A 13
User manual 128 pages
A 401-1
User manual 44 pages
A 401-1
User manual 128 pages
A 401
User manual 44 pages
A 401
User manual 112 pages
A 401
User manual 128 pages
AD 401
User manual 44 pages