How many heating circuits can the module control?
The module can control up to 4 heating circuits or up to 8 heating circuits when mixed. It can also handle up to 2 storage charging circuits.
What is the function of the temperature sensor in the heating circuit?
The temperature sensor in the heating circuit measures the supply water temperature or the temperature of the hot water storage. It is used to monitor and regulate the system's performance.
What should be done if the system freezes when not in use?
If the system is not in use and may freeze, ensure it remains powered on due to additional functions like hot water production or blockage protection. Address any faults immediately to prevent damage.
What is the purpose of the dew point sensor in the cooling circuit?
The dew point sensor in the cooling circuit sends a signal to the control system when the dew point is reached, preventing condensation by stopping the heating pump and avoiding further cooling.
What is the maximum number of MM100 modules allowed in one installation?
The maximum number of MM100 modules allowed in one installation depends on the installed control unit. Up to 6 or 10 modules are permitted based on the control unit type.
What is the default position of the code switch at delivery?
At delivery, the code switch is set to position 0. The module is only registered in the control unit if the code switch is set to a valid position for a heating circuit or storage charging circuit.
What are the dimensions of the module?
The dimensions of the module are 151 mm (width) x 184 mm (height) x 61 mm (depth). Additional measurements can be found in Figure 2 on page 91.
What is the maximum allowable wire cross-section for the connection terminals?
The maximum allowable wire cross-section for the connection terminals is 2.5 mm² for the 230 V connection and 1.5 mm² for the low-voltage connection.
What is the function of the blockage protection feature?
The blockage protection feature monitors the connected pump and mixer motor. If they remain inactive for 24 hours, they are briefly activated to prevent them from seizing.
What is the recommended action if warm water temperatures exceed 60°C?
If warm water temperatures exceed 60°C or thermal disinfection is enabled, a mixing device must be installed to ensure safe operation and prevent scalding.
Related products from Bosch
Heatronic 3
User manual 6 pages
ISC-RSC2-S
User manual 6 pages
ISP-RSC2-110S
User manual 6 pages
CR 11
User manual 152 pages
CR 11 H
User manual 152 pages
Control CR 20 RF
User manual 40 pages
FLM-420-RLV8-S
User manual 24 pages
FLM-420-RLV8-S
User manual 40 pages
7738112943
User manual 40 pages
Deepfield Connect
User manual 48 pages
Deepfield Connect
User manual 68 pages
Rexroth SE311
User manual 40 pages
Rexroth LTH
User manual 60 pages
MZ 100
User manual 64 pages
BSHC-2
User manual 114 pages
Rexroth SB356
User manual 124 pages
MU 100
User manual 154 pages
BMCT-SLZ
User manual 179 pages
BEA 040
User manual 196 pages
BEA 040
User manual 198 pages