Frequently Asked Questions
How to set the motor direction?
To set the motor direction, use the DIP switches SW2. Set SW2 to 'INV' for motor 1 or motor 2 to reverse the direction. Ensure the motor is properly connected and the encoder is functioning for accurate control.
What is the maximum power for the flashing output?
The maximum power for the flashing output is 230V~500W. This output is used for the flashing light and must be connected to a compatible load to avoid damage to the system.
How to connect the photocells?
To connect the photocells, use the CN2 terminal block. Ensure the photocells are connected to the correct terminals (DS2 and DS1) and that the shorting block is removed to allow proper operation.
What is the minimum cable section for the main power supply?
The minimum cable section for the main power supply is 2 x 1.5 mm² for lengths up to 20 meters. For longer lengths, use 2 x 2.5 mm² to ensure safe and efficient power delivery.
How to configure the motor delay settings?
To configure the motor delay settings, use the DIP switches SW1. Set the delay for motor 1 or motor 2 based on the required timing for the gate operation. Ensure the motor is properly connected and the encoder is functioning for accurate control.
What is the operating temperature range?
The operating temperature range for the control unit is from -20°C to 55°C. Ensure the unit is installed in an environment within this range to maintain optimal performance and safety.
How to connect the remote control?
To connect the remote control, use the radio channel AUX terminal. Ensure the remote control is properly paired with the system and that the antenna is correctly connected for reliable signal transmission.
What is the maximum number of codes that can be stored?
The system can store up to 120 codes, including CODE PP and CODE PED/2°CH. Ensure the codes are programmed correctly to avoid interference and ensure secure operation.
How to adjust the motor sensitivity?
To adjust the motor sensitivity, use the TRIMMER SENS. Turning the trimmer towards the '+' increases the sensitivity, allowing the motor to detect obstacles more effectively. Ensure the encoder is connected for accurate detection.
What is the purpose of the emergency stop button?
The emergency stop button is used to immediately halt the gate operation in case of an emergency. Ensure the button is easily accessible and properly connected to the system for quick and safe response.