Product description:

The Kimo TRANSOMIK BC2 is a control unit designed for use in industrial and commercial environments. It features a robust construction suitable for installation in challenging conditions. The device supports various input and output signals, enabling integration with different types of sensors and actuators. It includes a user-friendly interface for configuration and monitoring, and it is equipped with protective functions to ensure reliable operation. The TRANSOMIK BC2 is ideal for applications requiring precise control and monitoring of processes.

Frequently Asked Questions

What is the maximum power rating for TRANSOMIK® BC?

The TRANSOMIK® BC braking choppers are suitable for use with frequency inverters in the power range up to 1200 kW. This includes both the BC1 and BC2 models, with BC2 being designed for higher power applications.

What are the main differences between BC1 and BC2 models?

The BC1 model is a compact braking chopper suitable for applications up to approximately 35 kW peak braking power. The BC2 model is designed for higher power applications, up to 1200 kW, and includes additional control and monitoring functions such as fault detection and electronic overload monitoring.

What is the standard brake voltage threshold for BC1?

The standard brake voltage threshold for the TRANSOMIK® BC1 model is set to DC 770 V. It can be adjusted to DC 670 V using a switch located under the removable cover.

Can the BC2 model be used for continuous braking applications?

Yes, the BC2 model is suitable for quasi-continuous braking applications, such as hoisting drives and centrifuges with heavy-duty braking. It also supports parallel operation for higher braking power requirements.

What are the environmental conditions for operating TRANSOMIK® BC?

The TRANSOMIK® BC models are designed to operate in ambient temperatures ranging from 0°C to +40°C for normal operation. They can also be used in environments with temperatures up to +60°C for short periods, provided that cooling air is clean and non-corrosive.

What is the insulation voltage rating for TRANSOMIK® BC?

The insulation voltage rating for TRANSOMIK® BC1 and BC2 models is AC 300 V. For the BC2/575 and BC2/690 models, the insulation voltage rating is AC 400 V.

What are the available cooling options for BC2 models?

The BC2 models offer two cooling options: convection cooling for standard applications and fan-assisted cooling for higher power and continuous braking applications. The fan option helps maintain optimal operating temperatures during heavy-duty use.

What is the maximum braking power for BC2/690 model?

The BC2/690 model is designed for use with 3AC 660...690 V +10% line voltages and has a brake voltage threshold of DC 1065/1155 V. It supports peak braking power up to 1700 kW, making it suitable for high-power industrial applications.