Product description:
Frequently Asked Questions
How many boilers can be connected in cascade with the AVS 75.391 accessory?
The AVS 75.391 accessory allows managing a heating system with a maximum of 16 boilers connected in cascade, along with an optional separate storage for domestic hot water.
What components can the AVS 75.391 control directly?
The AVS 75.391 can directly control up to three independent relay outputs, two temperature sensors, one high-voltage thermostat connector, and one command input, such as an ambient thermostat.
What is required for the proper functioning of the system with the AVS 75.391?
An interface unit OCI 345 must be installed on each boiler in the cascade setup. Additionally, a remote control is required for using the AVS 75.391 accessory.
How should the AVS 75.391 be installed on the wall?
Install the device on the wall using the two pressure screws provided with the accessory, utilizing the holes in the electrical box. Ensure the unit is connected to the master boiler and other accessories as described in chapter 3. Fix the cable for power supply, use the mounting holes for wall fixing, and provide a conduit for external electrical accessories.
What type of electrical cable should be used for connecting the AVS 75.391 to the boiler?
Use a harmonized cable 'HAR H05 VV-F' with a cross-section of 2x0.5 mm² for a maximum length of 150 meters, connecting the two-pole terminal block of the AVS75 unit to the M2 (2-3) terminal block of the boiler.
How should the AVS 75.391 be connected to external accessories?
Connect the cascade pump to the QX21 connector of the AVS75, the cascade outlet probe to the BX21 connector (QAD36 provided), the cascade return probe (if applicable) to the BX22 connector (QAD36 available as an accessory), the ambient thermostat to the H2 connector, and the boiler pump (if installed) to the QX22 connector. Connect the corresponding NTC probe to the M2 terminal block of the master boiler.
What is the function of the OCI 345 interface unit?
The OCI 345 interface unit is an electronic device that enables communication via a bus between the boilers in the cascade setup. Each boiler must be connected to an OCI 345 accessory, and the connections should be made using a harmonized cable 'HAR H05 VV-F' with a cross-section of 2x1.5 mm² for a maximum length of 200 meters.
How do you access the parameters for the AVS 75.391?
To set parameters, use the Control Panel. For connecting the accessory in the boiler, refer to the boiler's instruction manual. The procedure involves rotating the knob B, pressing the knob B, pressing both the A and B buttons together, and using the A or C button to navigate through the menu options.
What is the process for configuring the master boiler?
Enter menu 3 using the control panel as described in chapter 4 and set the following parameters: Configuration Line 5977 to 'None', Line 6020 to 'Multifunctional', Line 6030 to 'Circulating Pump 1 Q2', Line 6040 to 'Common Outlet Probe B10', Line 6041 to 'Cascade Return Probe B70', Line 6046 to 'Ambient Thermostat CR1', and Line 6200 to 'Yes'.
How do you save the configuration after setting up the system?
After completing the system configuration, access menu 2 as described at the beginning of this chapter, select 'Configuration', then 'Line 6200', and confirm the selection by pressing the B button.
Related products from Siemens
SIPART PS2
User manual 56 pages
SIPART PS2
User manual 64 pages
SIPART PS2
User manual 68 pages
SIPART PS2
User manual 72 pages
SIPART PS2
User manual 84 pages
SIPART PS2
User manual 93 pages
SIPART PS2
User manual 304 pages
ET 200eco PN
User manual 118 pages
ET 200eco PN
User manual 138 pages
SIPART DR21
User manual 62 pages
SIMATIC ET 200AL
User manual 98 pages
SIMATIC ET 200AL
User manual 130 pages
SIPART PS2 PA
User manual 64 pages
SCALANCE WLC711
User manual 60 pages
6DR2100
User manual 50 pages
6GK1561-1AA01
User manual 66 pages
SIPART DR19
User manual 94 pages