Tusa RS-520 (80 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum depth for the RS-340 regulator?
The RS-340 regulator is intended for use up to a maximum water depth of 50 meters (164 feet). It is also restricted to use above water temperatures of 10°C.
Which TUSA regulators are certified for cold water diving?
The RS-340, RS-350, RS-520, RS-530, RS-560, RS-670, RS-680, RS-811, RS-811S, RS-812, RS-812S, and RS-860 regulators are certified for cold water diving and comply with EN250:2014 standards.
What is the purpose of the venturi adjustment lever on some TUSA regulators?
The venturi adjustment lever on regulators like the RS-680, 790, 811, 811S, 812, 812S, and 1001 allows the diver to utilize the natural venturi effect for power-assisted breathing underwater and adjust the lever to prevent free flow during surface swimming.
What is the function of the swivel joint on the second stage of the regulator?
The swivel joint on the second stage of the RS-340, 350, 670, 680, 812, and 812S regulators provides flexibility in the low-pressure hose, eliminating tension at the mouthpiece for a more natural and comfortable bite.
What should you do before using a TUSA regulator for the first time?
Before using a TUSA regulator, you must read the manual completely. Ensure the regulator is inspected visually and functionally, and never use it if it shows signs of damage or substandard performance.
What is the purpose of the S.E.A. feature on the RS-680 regulator?
The S.E.A. (Sequential Exhaust Assist) feature on the RS-680 regulator is an auxiliary exhaust valve located on the S-80 elliptical case, designed to reduce primary exhaust resistance for smoother breathing.
How should you clean the regulator after a dive?
After each dive, the regulator should be cleaned, inspected, and prepared for the next use or storage. It should be soaked in warm water (not exceeding 50°C or 122°F) to remove salt and mineral deposits, and the purge button should be depressed several times while submerged.
What is the recommended way to connect the first stage to the cylinder valve?
To connect the first stage to the cylinder valve, position the yoke or DIN adaptor in the center of the cylinder valve connection, and hand-tighten the screw. Ensure the O-ring is intact and avoid over-tightening to prevent damage.
What is the role of the first stage in the regulator system?
The first stage of the regulator reduces high-pressure air from the scuba cylinder to an intermediate pressure of approximately 135 PSI (9.5 bar), preparing the air for further reduction by the second stage to ambient pressure for breathing.
What is the function of the second stage in the regulator system?
The second stage of the regulator further reduces the intermediate pressure air from the first stage to ambient pressure, allowing the diver to breathe comfortably. It includes a demand valve that opens when the diver inhales, providing a natural and smooth breathing experience.