Product description:

The Control Nice mindyA924 is a control unit designed for use in automation systems. It features a compact design and reliable performance, making it suitable for a variety of applications. The device supports multiple communication protocols and offers easy integration into existing systems. It includes a user-friendly interface for configuration and monitoring. The mindyA924 is built to withstand demanding environments and ensures stable operation over a long period of time.

Frequently Asked Questions

How to mount the A924 control unit?

Install the unit on a permanent surface that is perfectly flat and adequately protected against knocks, ensuring the bottom remains at least 40 cm from the ground. Install cables or pipes only at the bottom of the unit. Fit the two screws into the relative upper holes by sliding them along the guide and partially tighten them. Rotate the control unit 180° and do the same with the other two screws. Fix the control unit to the wall. Fit the cover as required and press hard where shown by the arrows. To remove the cover, press on the hinge with a screwdriver and push up.

What type of cable should be used for electrical connections?

Use a cable with a minimum cross-section of 1 mm² to connect the flashing light and the electrical block. Wires with a minimum cross-section of 0.25 mm² must be used for very low voltage safety circuits. For connections to SUMO, use a 3x2.5 mm² cable for the motor (use 4 mm² if over 10m long) and a 2 x 0.75 mm² cable for the encoder.

What is the purpose of the phototest function?

The 'Phototest' function is an excellent solution for the reliability of safety devices. It puts the control unit and photocell assembly into category 2 as per UNI EN 954-1 standard. Connect the photocells as shown in one of the figures and move Dip-Switch 7 to On to activate 'Phototest'.

How to check if the motor is turning in the correct direction?

Release the motor and check that the release led on the board is on. Move the door manually so that it is free to move during the opening and closing manoeuvres. Block the motor again and check that the release led is off. Press the 'Close' button and check that the door moves in the close direction. If the opening manoeuvre is performed, press the 'Close' button again to stop the door from moving, unplug the machine, and invert the two motor wires.

What is the function of the 'OK' LED?

After about 2 seconds from switching on, the 'OK' LED should show the control unit is working correctly by flashing regularly at 1 second intervals. This indicates that the control unit is functioning properly after power is applied.

How to perform an initial search for mechanical stops?

Release the motor and move the door manually so that it is free to move during the opening and closing manoeuvres. Block the motor. Briefly press the 'Open' button or the 'Close' button on the board or give a command impulse to the inputs and wait for the control unit to perform a slow closing manoeuvre to position 0, a slow opening manoeuvre to position 1, and a rapid closing manoeuvre.

What are the different positions in the control unit?

Position 0 is the point at which the sectional door is in the closed position, corresponding to the mechanical stop (generally the floor). Position 1 is the point at which the sectional door is in the maximum open position, corresponding to the mechanical opening stops. Position A is the point at which the door is required to stop during the opening manoeuvre. Position B is the position in which the door is required to stop during the partial opening manoeuvre. Position RA is the position in which the door is required to begin slowing down during the normal opening manoeuvre. Position RC is the position in which the door is required to begin slowing down during the closing manoeuvre.

What is the function of the 'Stop' input?

The 'Stop' input is an input with STOP function (Emergency, shutdown or extreme safety). It is used to stop the door movement in case of an emergency or safety issue. When the 'Stop' input is activated, the control unit will stop the door movement immediately.

How to check if the safety devices are working properly?

Check that all the safety devices of the unit are in proper working order (emergency stop, photocells, pneumatic edges, etc.). Each time they cut in, the relative 'Stop', 'Photo' or 'Photo2' LEDs should turn off. This ensures that the safety devices are functioning correctly and providing the necessary protection.

What is the function of the 'Memory' button?

The 'Memory' button is used for memorisation procedure and manual programming of mechanical stops. It allows the user to store and recall the positions of the mechanical stops, ensuring accurate control of the door movement.