Product description:

The Otto Bock 13E202-50 is a control unit designed for use in prosthetic and orthopedic devices. It features a compact and durable construction, ensuring reliable performance in various applications. The device allows for precise control and adjustment, making it suitable for users requiring fine motor control. It is equipped with intuitive interface elements that facilitate easy operation. The control unit is compatible with a range of systems and can be integrated into different types of assistive technologies. Its design emphasizes user comfort and ease of handling, supporting long-term use without discomfort.

Frequently Asked Questions

What frequency does the product support?

The product supports two frequencies: 50 Hz (13E202=50) and 60 Hz (13E202=60). These frequencies are used for different regional power standards.

Who is qualified to use this product?

Only orthopedic technicians are qualified to use this product. It is intended for use by qualified personnel only.

What is the purpose of this product?

This product is exclusively for controlling myoelectric components of upper limb prostheses. It captures muscle action potentials from the skin surface and filters out unwanted signals.

What should I do if the product is damaged?

If the product is damaged, stop using it immediately and contact the authorized Ottobock service center for repair. Do not attempt to repair it yourself.

How do I connect the product to the electrode cable?

To connect the product, cut the electrode cable to the required length, insert it into the connector with the gray side up, and apply silicone grease to the contacts. Ensure the connection is secure and wipe away any excess grease.

What should I do if the electrode cable is damaged?

If the electrode cable is damaged, disconnect the system and contact your orthopedic technician. Do not use the product until the cable is replaced.

How do I adjust the sensitivity of the product?

Use the adjustment pin to set the sensitivity of the product. After a 10 to 15-minute break, recheck and adjust the sensitivity to ensure optimal control for the patient.

What should I do if liquid enters the product?

If liquid enters the product, stop using it immediately. Liquid damage can cause unexpected behavior or malfunction, and the product should not be used for waterproof applications.

What is the recommended distance from HF communication devices?

To avoid interference, maintain a minimum distance of 0.99m from GSM phones, 0.7m from UMTS devices, 0.35m from DECT phones, 0.22m from WLAN devices, and 0.22m from Bluetooth devices.

What should I use to clean the product?

Clean the product only with a damp cloth and mild soap. Avoid using solvents like acetone or gasoline, as they can damage the housing or components.