Astralpool BASIC (104 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum operating temperature for the valve?
The valve is designed to work with clean water at temperatures not exceeding 35ºC. It is important to ensure that the water temperature remains within this range to maintain optimal performance and prevent damage to the internal components.
What is the maximum working pressure of the valve?
The maximum working pressure of the valve is 350 kPa (3.5 bar). This pressure limit must not be exceeded during operation to avoid potential damage to the valve and ensure safe functioning.
What is the protection rating of the electronic module?
The electronic module has an IP-65 protection rating, which means it is dust-tight and protected against water jets from any direction. This ensures reliable operation in various environmental conditions.
What is the power supply requirement for the valve?
The valve requires a power supply of 115-230 VAC (50-60 Hz). It is essential to use the correct voltage to avoid damaging the electronic components and to ensure proper operation.
How should the valve be installed in relation to the filter?
The valve should be installed in the filter following the instructions provided in the hydraulic connection diagram. The installation must be carried out in accordance with the specific instructions for each particular implementation to ensure correct water circulation and safe operation.
What is the purpose of the pressure switch in the valve?
The pressure switch in the valve determines the saturation pressure of the filter and initiates a washing and rinsing process when necessary. It is factory-set to an operating pressure of 200 kPa (2 bar), but should be adjusted for each installation to ensure the correct operation of the filter cleaning system.
What safety precautions should be taken during installation?
During installation, it is essential to ensure that all electrical connections are properly made and verified. The valve must be installed in accordance with national installation regulations, and all contact with moving parts must be avoided until the system is fully powered down. Only qualified and authorized personnel should perform installation and maintenance tasks.
What should be done before performing maintenance on the valve?
Before performing any maintenance on the valve, it is recommended to remove electrical power to the valve, lock the switch-on devices, and verify that there is no electrical power being applied to the circuits. These steps ensure that the maintenance work is carried out safely and without risk of electric shock.
What is the intended use of the valve?
The valve is specially designed to be applied in pool filtration systems using a sand filter. It is intended for use in swimming pools and other similar applications that require efficient water filtration. The planned number of operations is sufficiently dimensioned for this application, and it should not be used for other purposes without consulting the manufacturer.
What is the maximum height at which the valve can be installed?
The valve can be installed at a maximum height of 2,000 meters above sea level. This specification ensures that the valve operates correctly under varying atmospheric conditions and maintains its performance in different environments.