Product description:
Frequently Asked Questions
What are the safety warnings for the ESP-CA controllers?
The ESP-CA controllers come with critical safety warnings to prevent electric shock, fire, and serious injury. Users must read all safety warnings and instructions, including those from the separately provided safety instructions n° 6159931790. Failure to follow these warnings and instructions can result in severe consequences. All warnings and instructions should be saved for future reference.
How do I start up the ESP-CA controller?
To start up the ESP-CA controller, turn the unit on using the on/off switch on the back panel. The unit will perform a general system check and display the first screen. Ensure the unit is properly grounded and that all safety precautions are followed before operating.
How do I navigate the menu on the ESP-CA controller?
To navigate the menu, use the knob on the front panel. Turn the knob to move through fields, push and turn to enter and modify values, and push again to save. Press ESC to go back or exit. The unit automatically saves values when moving between screens.
What are the programming options for the ESP-CA controller?
The ESP-CA controller can be programmed through the menu to set parameters such as program number, torque, joint type (hard or soft), and tightening time. These settings can be adjusted using the knob and encoder, and saved for future use. The unit supports up to 8 individual programs or an external program (EXT).
How do I set the torque level on the ESP-CA controller?
The torque level is set as a percentage of the torque range of the selected tool. For example, a 50% setting on a hard joint results in an assembly torque of approximately 6 Nm. This value should be confirmed and adjusted using a torque tester. The torque level is displayed on the main screen.
What is the purpose of the final phase (approach time) in the ESP-CA controller?
The final phase, or approach time, is used when tightening a hard joint. It determines the duration during which the screwdriver operates at the selected speed before reducing to the tightening speed. This time helps ensure accurate torque application and is adjustable between MIN and 10 seconds.
What should I do if the torque is reached during the final phase?
If the torque is reached during the final phase, a NOK message is displayed on the screen with three audible sounds. The output signals 'ERROR' and 'TORQUE' are transmitted simultaneously. This indicates that the tightening process has completed, and the tool may automatically start an untightening cycle if configured.
What are the safety precautions for using the ESP-CA controller?
To ensure safety, keep the work area clean and well-lit, avoid operating the tool in explosive atmospheres, and never use the cable to carry the tool or pull the plug. Always use proper personal protective equipment, including impact-resistant eye and face protection. Ensure the tool is properly grounded and never use unauthorized parts.
How do I modify the password and language settings on the ESP-CA controller?
To modify the password, enter the current password and select 'CHANGE PWD' to set a new one. To change the language, navigate to the password/language screen, select 'LANGUAGE', and choose the desired option. The changes are saved by pushing the encoder.
What are the specifications of the ESP-CA controller?
The ESP-CA controller operates on 110/230 V AC at 50/60 Hz, with a voltage of 40 VDC and a power rating of 200 VA. It includes a 3.15 A fuse and is classified as Class 1. The unit weighs 4.0 kg and has dimensions of 208 x 125 x 225 mm.
Related products from Desoutter
6159360740
User manual 40 pages
6159327070
User manual 44 pages
ESP1-HT
User manual 44 pages
ESP1-HT PLUS
User manual 44 pages
SLB
User manual 52 pages
CVIC II
User manual 578 pages
ESP2-A
User manual 172 pages
ESP-CA LT 230
User manual 296 pages
ESP-CA 230
User manual 296 pages
ESP-CA LT 110
User manual 296 pages