Product description:
Frequently Asked Questions
What is the purpose of the OPSO safety shut-off device?
The OPSO (Over-Pressure Shut Off) device is a self-acting safety mechanism that protects connected gas appliances from excessive pressure. It continuously monitors the output pressure and automatically shuts off the gas supply if the pressure exceeds the set limit. The indicator changes from green to red when the device activates, and it must be manually reset after addressing the issue.
How does the PRV (Pressure Relief Valve) function?
The PRV (Pressure Relief Valve) is a self-acting safety device that protects connected consumers from excessive pressure. If the output pressure becomes too high, such as due to elevated temperatures, the PRV opens and releases the excess pressure through the vent port. After the pressure drops, the PRV closes automatically. A vent line must be connected to the vent port when operating in a building or enclosed area.
What is the function of the thermal shut-off device 'T' (TAE)?
The thermal shut-off device 'T' (TAE) automatically cuts off the gas supply when the temperature reaches 100°C. This prevents overheating and potential hazards. After the device activates, the unit must be replaced. The device is marked on the product's type plate with the letter 'T'.
What should be done if the gas flow exceeds the rated capacity?
If the gas flow exceeds the rated capacity, the gas supply is automatically shut off to prevent overpressure. This can occur if a valve is opened or a plug is removed, causing a pressure drop. The gas flow must be restricted to the rated capacity to avoid triggering the safety mechanisms.
How should the product be installed to ensure safety?
Installation must be performed by a qualified professional and must follow all safety guidelines. Ensure the product is mounted in a location that allows for proper ventilation to prevent gas accumulation. Avoid tight spaces and ensure all connections are secure and leak-free. The product must be installed in accordance with the technical regulations for liquefied gas.
What are the steps to reset the OPSO after it has activated?
To reset the OPSO after it has activated, first close the gas withdrawal valve. Then, release the pressure by disconnecting the output and inlet connections. Re-tighten all connections, and open the gas withdrawal valve again. Manually reset the OPSO by removing the protective cap and using the release mechanism. Ensure the indicator turns green before rechecking for leaks.
What is the purpose of the gas flow monitor (GS)?
The gas flow monitor (GS) stops the gas flow if the volume exceeds a predetermined limit. It allows only a small amount of gas to pass through a small overflow opening. Once the gas pressure stabilizes, the GS opens. It remains open during normal operation and shuts off the gas supply if the flow exceeds the rated capacity.
Handle the product with care to avoid injury from gas leaks or sparks. Ensure all connections are leak-free and secure. Avoid using open flames near the product during testing. If a gas leak is detected, immediately shut off the gas supply and contact a qualified professional. Always wear protective gear, including safety glasses, to prevent eye injuries from metal shavings.
How should the product be tested for leaks?
Before putting the product into operation, test all connections for leaks using a foam-based leak detection spray (EN 14291). Apply the spray to all connection points and look for bubbles. If bubbles form, tighten the connections. If leaks persist, do not operate the product. For more detailed testing, use a pressure test kit (DFP25) and follow the instructions in the manual.
What are the maintenance requirements for the product?
The product requires no maintenance after proper installation and commissioning. Regularly inspect all connections for leaks and ensure they remain secure. Avoid using improper tools during installation or maintenance. If any issues arise, contact the manufacturer for inspection or replacement.
Related products from GOK
ODRE-M
User manual 12 pages
ODRE-M
User manual 24 pages
ODRE-M
User manual 36 pages
ODRE
User manual 12 pages
ODRE
User manual 24 pages
ODR
User manual 12 pages
ODR
User manual 24 pages
ODR
User manual 36 pages
Caramatic Basic Two
User manual 24 pages
VSR 0126
User manual 38 pages
VSR 0126
User manual 64 pages