Hach SC200 (146 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the measuring range for the conductivity module with cell constant 0.05?
The conductivity module with a cell constant of 0.05 has a measuring range of 0 to 100 microsiemens per centimeter (µS/cm).
What is the response time of the conductivity module?
The response time of the conductivity module is 0.5 seconds, ensuring quick and accurate readings during operation.
What is the precision of the conductivity module for readings between 20 and 200,000 µS/cm?
The precision of the conductivity module for readings between 20 and 200,000 µS/cm is ±0.5% of the measured value, ensuring reliable and consistent results.
What is the maximum cable length for the conductivity module?
The maximum cable length for the conductivity module is 91 meters (300 feet), allowing for flexible installation in various environments.
What is the warranty period for the conductivity module?
The conductivity module comes with a 1-year warranty, with an extended 2-year warranty available in the European Union (EU).
What safety precautions should be taken when installing the module?
When installing the module, ensure that all electrical connections are made with the power disconnected to prevent electrocution. Also, avoid exposing the sensor to high electromagnetic fields, which can affect measurement accuracy.
What should be done if the sensor cable is not long enough to reach the controller?
If the sensor cable is not long enough to reach the controller, an interconnect cable and junction box are required to extend the distance, ensuring proper signal transmission and system integrity.
What are the requirements for connecting the sensor to the module?
To connect the sensor to the module, ensure that all sensor ground and shield wires are properly connected to the controller enclosure grounding screws. Follow the wiring diagram provided in the manual to avoid damage to the internal components.
What is the purpose of the Modbus registers listed in the manual?
The Modbus registers listed in the manual are used for network communication between the module and other devices, allowing for data exchange and remote monitoring of the system.
What should be done if the module is exposed to high-frequency electromagnetic fields?
Exposure to high-frequency electromagnetic fields in the 700–800 MHz range can cause inaccurate results. Ensure that the module is installed in an environment free from such interference to maintain measurement accuracy.