Product description:

The Honeywell NTC 20 controller is designed for precise temperature regulation in various industrial and commercial applications. It features a robust construction suitable for harsh environments and offers reliable performance under demanding conditions. The device includes multiple input and output options for integration with different systems. It supports a wide range of temperature sensors and provides accurate control through its advanced algorithms. The controller is easy to install and configure, making it a versatile solution for temperature management in heating, ventilation, and air conditioning systems.

Frequently Asked Questions

What is the software version of the SDC controller?

The manual is valid for software version V 3.2 of the controller. The software version is displayed for approximately 8 seconds after turning on the device. If you are using an older version, contact a heating specialist.

What are the safety precautions for installation?

The heating system must be fully installed and filled with water to prevent pump damage. All electrical connections must be done by a qualified electrician according to VDE standards. If floor heating is connected, a temperature limiter must be installed after the pump to prevent overheating.

What are the electrical requirements for the controller?

Use 1.5 mm² cables for 230 V lines, 0.6 mm² for bus lines, and 0.5 mm² for sensor and analog signals. Ensure all cables are properly insulated and installed according to local regulations.

What is the maximum cable length for sensors and analog inputs?

A maximum of 200 meters is recommended for sensor and analog inputs. Longer cables may increase the risk of electromagnetic interference. Relays can use unlimited cable lengths.

How to connect a room sensor RF 20?

The room sensor RF 20 should be connected according to the wiring diagram provided. Ensure all connections are secure and insulated to prevent electrical faults.

What is the purpose of the anti-Legionella function?

The anti-Legionella function automatically heats the hot water to a temperature of 65 °C at a selected time and date to kill Legionella bacteria in the hot water tank.

What is the hand operation mode used for?

In hand operation mode, the boiler can be heated to its maximum temperature, and all pumps and mixers are activated. This mode is used for emissions testing or when the controller is faulty. It should be used with caution due to the risk of scalding.

How to connect a wall module TF 22 / TFU 22?

The wall module TF 22 / TFU 22 should be connected according to the wiring diagram. Ensure that all connections are made correctly and that the module is properly grounded.

What are the technical specifications of the SDC controller?

The SDC controller has a range of technical specifications, including sensor resistance values (NTC 20, PT 1000), measurement ranges, and digital input capabilities. These specifications are detailed in the technical data section of the manual.

How to clean the controller?

The controller is maintenance-free. It can be cleaned externally with a damp (not wet) cloth. Avoid using harsh chemicals or abrasive materials to prevent damage to the surface.