Lutron GRAFIK Eye QS (144 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Lutron GRAFIK Eye QS is a high-performance lighting control system designed for commercial and residential applications. It offers advanced dimming capabilities and integrates seamlessly with various lighting sources, including LED, fluorescent, and incandescent lamps. The controller features a user-friendly interface and supports multiple control methods such as wall switches, occupancy sensors, and daylight harvesting. It is compatible with a wide range of Lutron products and can be programmed to meet specific lighting needs. The GRAFIK Eye QS is known for its reliability, energy efficiency, and ease of installation, making it a popular choice for lighting control solutions.

Frequently Asked Questions

How many zones can the GRAFIK Eye QS System support?

The GRAFIK Eye QS System can support up to 100 zones and 100 devices. Each zone can have a maximum load of 500 watts, and the total lighting load per unit is limited to 10 A.

What are the model numbers and wattage ratings for the GRAFIK Eye QS System?

The available models are QSG - 3PCE (1500 watts), QSG - 4PCE (2000 watts), and QSG - 6PCE (2300 watts). All units operate at 230 V, 50/60 Hz. Each zone has a capacity of 500 watts.

What types of lighting loads are supported by the GRAFIK Eye QS System?

The system supports various lighting loads including incandescent, magnetic low-voltage (MLV), electronic low-voltage (ELV), Hi-Lume/Eco-10, non-dim, neon/cold cathode, and Tu-Wire. ELV lighting must be rated for reverse phase control dimming.

How do you set the high and low end trim for a zone?

To set the high and low end trim, enter programming mode, navigate to 'Zone setup,' and select 'High end' or 'Low end.' Use the zone raise/lower buttons to adjust the trim levels. The info screen will display the zone number and percentage as you adjust.

Can you set a minimum lighting level for dimming zones?

Yes, you can set a minimum lighting level for dimming zones. Enter programming mode, navigate to 'Zone setup,' and select 'Min level.' Choose 'OFF' for lights to turn off completely or '10%' for the minimum light level. The info screen will confirm the setting.

What are the preprogrammed functions for the lighting column buttons?

For dimmable loads, the preprogrammed functions are: Scene 1 (100%), Scene 2 (75%), Scene 3 (50%), Scene 4 (25%), and Scene OFF (0%). For non-dim loads, Scene 1 to 4 turn all lights on, and Scene OFF turns them all off.

How do you install the GRAFIK Eye QS System?

Mount the control unit in a 4-gang wallbox with at least 110 mm (4.5 in.) clearance above and below the faceplate. Connect the line voltage/mains, ground, and load wires to the appropriate terminals. Ensure all connections are secure and follow local electrical codes.

What is the recommended torque for installing the GRAFIK Eye QS System?

The recommended installation torque for line voltage/mains connections and earth/ground connections is 0.6 N•m (5.0 in.-lbs.). Ensure all connections are tightened to this specification to prevent overheating or damage to the control unit.

What types of wiring are used for the GRAFIK Eye QS System?

The system uses Class 2/PELV low-voltage wiring for communication. Control power uses two 1.0 mm² (#18 AWG) conductors, and data link uses a twisted, shielded pair of 1.0 mm² (#22 AWG) wires. Follow local electrical codes for installation.

How do you connect the IR receiver and occupant sensor?

Connect the IR receiver and occupant sensor to the appropriate terminals on the control unit. The IR DATA and IR COM terminals are used for the IR receiver, while the occupant sensor uses OCC SIG, 24 V, and OCC COM terminals. Ensure all connections are secure and follow the wiring diagram.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.