Lascar Electronics EL-USB-3 (17 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What measurements does the EL-USB-3 record?
The EL-USB-3 records both temperature and relative humidity using its internal sensor. It time-stamps each measurement pair to provide correlated environmental data, which is useful for monitoring storage conditions and detecting trends or excursions over time.
What is the temperature measurement range and accuracy?
The device measures temperature from -35°C to +80°C with an accuracy of approximately ±0.3°C. This range and precision make it suitable for most environmental monitoring tasks, and regular verification helps ensure reliable, traceable results.
What is the humidity measurement range and accuracy?
Relative humidity is measured across the full 0% to 100% RH range with an accuracy around ±2% RH. Such performance is appropriate for storage and climatic monitoring, and avoiding condensation on the sensor preserves long-term accuracy.
How many readings can the EL-USB-3 store?
The logger stores up to 16,000 time-stamped readings, typically saved as temperature and humidity pairs. This capacity supports extended monitoring periods before data offload, and choosing an appropriate sampling interval maximizes deployment duration.
How do I set the logging interval and start recording?
You configure the logging interval and start recording through the device's configuration interface when connected by USB. Select an interval that balances desired temporal resolution and battery/storage life, and use delayed start if you need a future deployment time.
How can I download logged data to a computer?
Logged data is transferred to a computer via the logger's USB connection. After connecting, the recorded data can be exported in common file formats for analysis, enabling you to visualize trends, generate reports, and archive environmental records.
Can the EL-USB-3 operate without a computer connected?
Yes, the EL-USB-3 is designed for standalone operation on its internal replaceable battery. It logs data autonomously in the field and only requires a computer when you need to configure settings or download stored measurements.
How long does the battery last and how is it replaced?
Battery life depends on the selected logging interval and operating conditions; lower sample rates extend life. The unit uses a replaceable battery accessed through a compartment, allowing quick exchange to minimize downtime while maintaining accurate logging.
Is the EL-USB-3 suitable for use in harsh or outdoor environments?
The logger features a rugged design for reliable performance in many indoor and sheltered environments. For sustained exposure to harsh weather, moisture, or direct sunlight, consider additional protective enclosures or positioning to prevent sensor damage.
How can I verify or calibrate the EL-USB-3's measurements?
Verify accuracy by comparing readings to a calibrated reference under controlled conditions. For traceable calibration, use accredited calibration services and schedule periodic checks, especially when measurements are required for compliance or critical process control.
What information does the built-in LCD display show?
The LCD provides real-time temperature and humidity readings along with status indicators such as logging activity and battery condition. This quick visual feedback is useful for on-site checks without a computer and helps confirm correct deployment.
Which accessories or mounting options are available for this logger?
Common accessories include wall or panel mounts, protective covers, and calibration certificates or services. Using appropriate mounting hardware and enclosures secures the logger and optimizes sensor exposure for consistent, repeatable environmental measurements.