Product description:
Frequently Asked Questions
How does the pump operate in manual mode?
In manual mode, the pump operates in constant mode, and the flow can only be manually regulated by pressing the keys simultaneously to increase or decrease it. The display shows the operating mode as 'Man' and the current dosage speed based on the selected unit of measurement.
How does the pump dose proportionally to a 0/4-20 mA signal?
The pump proportionally doses based on a 0/4-20 mA signal. By default, it interrupts dosage at 4 mA and doses at maximum frequency when receiving 20 mA. These values can be modified during programming or operation by pressing the keys simultaneously to increase or decrease the flow.
How does the pump dose proportionally to a 20-4/0 mA signal?
The pump doses proportionally to a 20-4/0 mA signal. By default, it interrupts dosage at 20 mA and doses at maximum frequency when receiving 4 mA. These values can be modified during programming or operation by pressing the keys simultaneously to increase or decrease the flow.
How does the pump dose proportionally to external impulses (multiplication)?
The pump doses proportionally to external impulses (multiplication) by making a programmed 'n' number of strikes for each signal received. It automatically adjusts the dosage frequency based on the time between signals. The timeout and memory settings can be modified during operation by pressing the keys simultaneously to increase or decrease the flow.
How does the pump dose in batch mode?
In batch mode, the pump can be started manually by pressing the keys or using a remote control. The quantity to be dosed in milliliters and the time for completion can be set. During operation, the quantity can be modified by pressing the keys simultaneously to increase or decrease the flow.
How does the pump dose in ppm mode?
In ppm mode, the pump doses proportionally to an external signal, automatically calculating the relationship between incoming signals and pump strokes based on the programmed ppm value. The ppm value, impulse/litre ratio, and product concentration can be set during programming or operation by pressing the keys simultaneously to increase or decrease the flow.
How does the pump perform timed dosing?
The pump performs timed dosing by setting a programmed quantity in milliliters, a delay time, and an interval between operations. These values can be modified during operation by pressing the keys simultaneously to increase or decrease the flow. The display shows the operating mode as 'Timer' and the current dosage status.
How can the maximum flow rate be set?
The maximum flow rate can be set by pressing the keys simultaneously to increase or decrease the value. The pump displays the flow in the selected unit of measurement, and changes can be confirmed by pressing the key to return to the main menu.
How can the alarm relay be configured?
The alarm relay can be set to either open or closed by pressing the keys simultaneously to increase or decrease the value. The default setting is open, and changes can be confirmed by pressing the key to return to the main menu.
How can the pump be calibrated for flow?
The pump can be calibrated manually by entering the cc value per stroke using the keys and confirming with the key. Alternatively, it can be calibrated automatically by making 100 strokes and entering the quantity sucked up by the pump using the keys, then confirming with the key.
Related products from seko
TEKNAEVO TPG
User manual 71 pages
TEKNAEVO TPG
User manual 95 pages
TEKNAEVO TPG
User manual 95 pages
PoolOne CS
User manual 42 pages
PoolOne RG
User manual 42 pages
PoolOne pH
User manual 42 pages
TWINDOSE 10
User manual 62 pages
TEKNAEVO TPG 603
User manual 71 pages
TEKNAEVO TPG 800
User manual 71 pages
WAREDOSE 35
User manual 147 pages