Product description:
Frequently Asked Questions
What gas is used to fill piston accumulators?
Piston accumulators must be filled with nitrogen only. Using oxygen or air can lead to explosion hazards. Always ensure the accumulator is filled with nitrogen as specified in the technical documentation.
How should piston accumulators be stored?
Piston accumulators should be stored in a dry, cool place, protected from direct sunlight. They can be stored for up to six months under these conditions. For longer storage, a long-term conservation method should be applied.
What is the maximum operating temperature for piston accumulators?
The permissible operating temperature varies depending on the material of the accumulator body and seals. It is indicated on the stamp, type plate, or in the conformity declaration. Always refer to the specific markings for accurate information.
What type of hydraulic fluid is recommended for use with piston accumulators?
Hydraulic accumulators should only be operated with hydraulic fluids that meet the cleanliness classes specified: NAS 1638 class 6 or ISO 4406 class 17/15/12. Using fluids outside these specifications can lead to operational issues and damage.
How do you check the charging pressure of a piston accumulator?
The charging pressure (p0) can be checked using the FPU filling and testing device or manually. For manual checks, ensure the accumulator is fully depressurized, then monitor the pressure gauge during the filling process. Always refer to the technical specifications for the correct pressure values.
What safety precautions are required when working with piston accumulators?
Only trained personnel should perform any work on piston accumulators. Ensure the gas side is fully depressurized before any maintenance or repairs. Avoid welding, burning, or mechanical work on the accumulator. Always follow the safety guidelines provided in the manual to prevent injury or damage.
How should piston accumulators be mounted?
Piston accumulators can be mounted in any orientation, but some systems require a vertical position with the gas valve oriented upwards. Ensure all markings, type plates, or labels are accessible and legible regardless of the mounting position. Leave sufficient space for maintenance around the gas filling port.
What is the recommended maintenance schedule for piston accumulators?
Regular maintenance should include checking the charging pressure (p0), inspecting connections for leaks, verifying the condition of valves and safety devices, and ensuring secure mounting. For continuous and high-speed operation, check for oil leakage on the gas side every few months to maintain optimal performance.
What should be done if oil is found on the gas side of the accumulator?
Oil on the gas side indicates a seal failure. Only trained personnel should handle this issue. Follow the detailed procedures in the maintenance manual to safely remove the oil and inspect the accumulator for damage. Do not attempt repairs without proper training.
What are the requirements for filling a piston accumulator with nitrogen?
Hydraulic accumulators must be filled with nitrogen classified as class 4.0. Any deviation from these specifications must be approved by HYDAC. Ensure the filling process is conducted by trained personnel and that the nitrogen pressure is within the specified limits to prevent overpressure or damage.