Log in


or


google Continue with Google

Already have an account?

ABB DELTAplus (340 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The ABB DELTAplus Energy Consumption Meter is designed for precise measurement of electrical energy consumption. It provides accurate readings of active and reactive energy, voltage, current, and power. The device supports various communication protocols and is suitable for use in industrial and commercial applications. Its robust construction ensures reliable performance in demanding environments. The meter features a user-friendly interface and can be easily integrated into existing electrical systems.

Frequently Asked Questions

How to install DELTAplus energy meter?

To install the DELTAplus energy meter, first turn off the power supply. Secure the meter on a DIN rail, connect the cables according to the wiring diagram, and tighten them with the specified torque. Install the circuit breaker as per the table, and verify the installation by connecting the meter to the correct voltage and checking the current flow through the transformers.

What tools are needed for installation?

For installation, you will need a T25 Torx or flat screwdriver for direct connection meters, a cross screwdriver #1 and a 4-5 mm flat screwdriver for meters connected via current and voltage transformers, and a standard flat screwdriver 2.5 mm for pulse and tariff outputs.

What is the standard torque for tightening connections?

For meters with direct connection, the tightening torque should be 2 Nm. For meters connected via current and voltage transformers, the torque should be 1 Nm. Ensure all connections are tightened properly to avoid measurement errors.

How to check the installation after connecting the meter?

After connecting the meter, apply the correct voltage as specified in the technical data section. For meters connected via transformers, verify the current flow and direction. Apply a load of at least 50 mA to the meter and allow it to perform an automatic system check.

What should I do if the meter displays an error?

If the meter shows an error, refer to the error code in the troubleshooting section of the manual. Check the error code and follow the recommended steps to resolve the issue. Ensure all connections are secure and the correct voltage is applied.

What are the standard values for the meter?

The standard values for the meter include a voltage transformer ratio of 1, a current transformer ratio of 1, a pulse frequency of 100 imp/kWh, and a default address of 0. These values may need adjustment depending on the meter configuration and transformer setup.

How to change the meter settings?

To change the meter settings, use the SET and SCROLL buttons to navigate through the menu. Press the SET button to enter the configuration mode, and use the SCROLL button to adjust the values. Confirm the changes by pressing the SET button again and return to the normal mode.

What are the functions of the meter buttons?

The SET button is used to change values, while the SCROLL button allows navigation between menus and adjustment of settings. A short press moves between menus, and a long press (more than 2 seconds) switches between modes. If no button is pressed for 2 minutes, the meter returns to the previous level.

What is the purpose of the meter's display symbols?

The display symbols on the DELTAplus meter indicate voltage phases, meter status, measurement units, load indicators, and operating modes. These symbols help users monitor the meter's performance and ensure accurate energy measurement.

What are the technical specifications of the meter?

The DELTAplus meter has a voltage range of 57-276 V, a frequency of 50 Hz, and a precision class that meets international standards. It supports both direct and transformer-based connections and includes features like pulse output, tariff inputs, and communication interfaces for data transfer.

Send answer

Related products from ABB

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.