Samoa 366761 (72 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum working pressure for the meter?
The meter is designed for precise measurement of low viscosity fluids and must not exceed the maximum unit working pressure. Always refer to the technical specifications for exact values.
What type of batteries does the meter use?
The meter requires two 1.5 V alkaline AAA batteries as the power supply source. Always use the correct battery type to ensure proper operation.
How do I reset the partial register?
To reset the partial register, press the RESET key when the display shows the word 'TOTAL'. This will reset both the partial register and the reset total.
What are the two operating modes of the meter?
The meter has two operating modes: Normal Mode, which displays partial and total dispensed quantities, and Flow Rate Mode, which displays flow rate along with partial dispensed quantity.
How do I enter calibration mode?
To enter calibration mode, press the CAL key quickly while the meter is in standby. This will allow you to adjust the calibration factor or restore the factory setting.
What happens if the battery level is low?
The meter has two low-battery alarm levels. When the first level is reached, a fixed battery symbol appears. If the second level is reached, the battery icon starts to flash, indicating the need for battery replacement.
How do I change the batteries?
To change the batteries, press RESET to update all totals, remove the old batteries, insert new AAA batteries in the same position, and close the cover. The meter will resume normal operation automatically.
What is the K factor in calibration?
The K factor, or calibration factor, is a multiplication factor applied by the system to the electrical pulses received, converting them into measured fluid units. It can be customized or restored to the factory default value of 1,000.
Can the meter be used in extreme flow conditions?
The meter is designed for normal operating conditions. However, in extreme flow rate conditions, an on-the-spot calibration may be required to ensure accurate measurements under real operating conditions.
How do I switch between calibration factors?
To switch between calibration factors, press the RESET key while in calibration mode to switch from the user factor to the factory factor. Confirm your choice by pressing CAL quickly while 'User' or 'Fact' is displayed.