Pitco SGH50 (44 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I check the oil level in the fryer?
Always ensure the oil level is above the minimum indicated level. Using old oil can be dangerous as it has a reduced flash-point and is more prone to surge boiling. Regularly check and replace oil as needed to maintain safety and performance.
What should I do if the fryer does not heat?
If the fryer does not heat, check if the hi-limit switch has tripped and reset it once the oil cools to 400°F + 20°F. Also, verify the heat demand relay and ignition module for faults. If the issue persists, consult a qualified technician.
How do I test the temperature probe?
To test the temperature probe, check its resistance and compare it with the probe resistance chart. If the probe returns an open circuit or 0 Ohms, it should be replaced. If the resistance varies more than 30 Ohms, it may need calibration or replacement.
What is the function of the hi-limit switch?
The hi-limit switch is a normally closed switch that trips when the temperature reaches 450°F ± 15°F. It interrupts the 24 VAC supply to the ignition module, preventing overheating. It must be reset once the oil cools to 400°F + 20°F.
How do I troubleshoot the pump not running?
If the pump is not running, check if the red return valve handle is fully open and the filter circuit breaker is in the on position. Also, ensure the filter motor thermal overload has not tripped and the power cord is properly connected.
What should I do if the fryer displays 'DRAINING'?
If the fryer displays 'DRAINING', verify that the blue drain valve is fully closed. Check the sensor switch for continuity and correct alignment. If the switch is defective or misaligned, replace or adjust it accordingly.
How do I reset the hi-limit switch?
To reset the hi-limit switch, allow the oil to cool to 400°F + 20°F. Once cooled, the switch should reset automatically. If it does not reset, it is defective and should be replaced by a qualified technician.
What is the purpose of the relay board?
The relay board controls the electrical circuits for the fryer, including the heat demand relay, side on relay, and indicators. It ensures proper power distribution and signaling between the controller, gas valve, and other components.