What is the SH ARC-GATEWAY used for?
The SH ARC-GATEWAY allows access to connected ARCNET networks via TCP/IP protocol. It runs on Linux, simplifying integration into customer IT infrastructures and subsequent administration.
How does communication with the SH ARC-GATEWAY work?
Communication occurs through TCP/IP sockets using specific packet types defined by the SOHARD protocol. Each data package includes a header containing protocol identification, packet type, and length in bytes.
What is OP_HELLO used for?
OP_HELLO informs the SH ARC-GATEWAY about the communication protocol being used. It must be sent as the first data package after opening a socket. If not received, the gateway closes the connection immediately.
How does OP_READ_REQUEST function?
OP_READ_REQUEST signals to the SH ARC-GATEWAY that the client wants to receive an ARCNET packet. The gateway starts receiving packets only if this command or OP_READ_CONTINUOUS is processed.
What happens when a read request fails?
If a read request in the ARCNET network is interrupted by an error or timeout, OP_READ_ERROR is sent to notify the client of the failure and provide relevant details about the issue.
How does OP_WRITE_DATA work?
OP_WRITE_DATA allows the client to send data to the SH ARC-GATEWAY for transmission to an ARCNET participant. It includes sender, destination IDs, and payload information in a structured format.
What is the purpose of OP_READ_CONTINUOUS?
OP_READ_CONTINUOUS enables or disables continuous reception mode on the gateway. When active, it allows automatic sending of data packets without requiring explicit read requests from the client.
How does the life sign request work?
OP_LIFE_SIGN_REQUEST activates a timer on the server side with a specified delay (minimum 10 seconds). The server sends an OP_LIFE_SIGN message when the timer expires, confirming active communication.
What is the function of OP_LIFE_SIGN?
OP_LIFE_SIGN is sent to the client when a configured timer on the gateway expires. This signal confirms that the system remains operational and responsive during extended periods without explicit data exchange.
How are multi-byte values stored in packets?
Multi-byte numerical values are stored using Little-Endian format, meaning lower-value bytes are placed at lower memory addresses for efficient processing across different systems.