Product description:
Frequently Asked Questions
How do you start the generator?
To start the generator, open the fuel valve (13) by turning it downward, set the on/off switch (10) to 'ON', position the choke lever (11) to 'I Ø I', and start the motor using the recoil starter (12) by pulling firmly on the handle. If the motor does not start, pull the handle again. After starting, move the choke lever (11) back to its original position.
What is the maximum power output of the generator?
The maximum power output of the generator is 2200 W, which can be achieved for a short period of up to 2 minutes (S2). The continuous rated power (S1) is 2000 W.
How do you stop the generator?
Before stopping the generator, run it briefly without load to allow the engine to cool down. Turn off the on/off switch (10), close the fuel valve (13), and ensure any connected electrical devices are disconnected.
What type of fuel does the generator use?
The generator uses unleaded normal gasoline as fuel. It is important to use only unleaded normal gasoline to avoid damage to the engine and ensure proper operation.
What is the capacity of the fuel tank?
The fuel tank has a capacity of 15 liters, providing sufficient fuel for extended use when operating the generator under normal conditions.
What is the rated voltage of the generator?
The rated voltage of the generator is 230 V alternating current (V~), suitable for powering standard household and small industrial appliances.
How often should the spark plug be inspected and cleaned?
The spark plug should be inspected for contamination after 20 hours of operation and cleaned using a copper wire brush if necessary. It should also be maintained every 50 hours of operation to ensure optimal performance.
What is the recommended oil type and quantity for the generator?
The generator requires approximately 0.6 liters of 15W40 motor oil. Only this specific type of motor oil should be used to ensure proper lubrication and engine protection.
What safety precautions should be taken when operating the generator?
When operating the generator, ensure it is placed on a stable, flat surface away from walls and other equipment. Avoid operating it in enclosed spaces or near open flames. Always keep the area clear of flammable materials and never operate the generator while refueling. Use appropriate personal protective equipment, including gloves, when handling hot parts or fuel.
What is the noise level of the generator?
The generator produces a sound pressure level (LpA) of 71.6 dB(A) and a sound power level (LWA) of 94 dB(A) with an uncertainty of ±1.9 dB(A). These levels are indicative of the emissions and should be considered when assessing potential risks in the working environment.