Product description:

The HERON 8896317 is a generator designed for reliable power supply in various applications. It features a robust construction and efficient performance, ensuring stable operation under different conditions. The unit is equipped with a fuel-efficient engine and includes essential components for immediate use. It is suitable for both stationary and mobile power generation needs, making it a versatile solution for industrial, commercial, and emergency power requirements.

Frequently Asked Questions

How to prepare the generator before starting?

Before starting the generator, ensure the following: Fill the oil tank with SAE 15W40 motor oil suitable for four-stroke engines, ensuring the oil level reaches the indicated pictogram. Check the oil level, as low oil levels may prevent starting due to oil level sensor protection. Use only SAE 15W40 oil from the same brand and avoid using different types of oil. Switch the operating switch to position '0' (OFF). Set the gas valve to 'OFF' according to the pictogram. Set the fuel valve to '0' according to the pictogram. Fill the fuel tank with fresh, high-quality unleaded gasoline, such as Natural 95 or 98, or an equivalent. Note that gasoline has a shelf life of only three months according to ČSN 65 6500, as volatile components evaporate and cause starting issues. It is recommended to use a fuel conditioner in the gasoline to address starting problems caused by poor fuel quality.

How to start the generator manually?

To start the generator manually, follow these steps: Open the fuel supply by switching the fuel valve to position '1'. Set the throttle lever to 'CLOSE'. Switch the operating switch to position 'I' and pull the starter rope to start the generator. After starting, set the throttle lever to 'OPEN' to prevent engine stalling.

How to switch the generator to gas fuel?

To switch the generator to gas fuel, follow these steps: Heat the engine for about 1 minute on gasoline. For LPG (propane-butane), press the 'gold' switch on the mixer; for NG (natural gas), pull the switch. Close the fuel supply by switching the fuel valve to '0' and wait until the engine produces an uneven sound due to lack of fuel. Then fully open the gas supply from the pressure tank and slowly open the gas supply to the generator by turning the lever to 'ON'. It is important not to rush during the transition from gasoline to gas and to gradually open the gas supply based on the engine sound, which may take 1-2 minutes.

How to turn off the generator?

To turn off the generator, follow these steps: Switch the operating switch to position '0' (OFF). Set the gas valve to 'OFF'. If gasoline was used, set the fuel valve to '0' to prevent liquid gasoline from entering the engine cylinder during handling, which would require servicing without warranty. Close the gas output from the propane-butane tank or gas supply line.

What precautions should be taken when using the generator?

When using the generator, ensure the following: If the generator is used as a backup power source for TN-C-S (TN-C) networks (fixed electrical installations in apartments, houses, etc.), it must be connected only by a qualified electrician, as the generator's IT network must be compatible with the TN-C-S (TN-C) network. The generator can only be connected to the TN-C-S (TN-C) network through a surge protector integrated into the TN-C-S (TN-C) network. If the generator is installed as a backup power source, it should be tested once or twice a month to ensure it is ready for emergency use. Before starting, read the entire user manual, keep it attached to the product, and ensure the operator is familiar with it. If the product is loaned or sold, include this manual. Avoid damaging the manual. The manufacturer is not liable for damages or injuries resulting from the use of the device in conflict with this manual. Familiarize yourself with all controls, safe operation, and shutdown procedures to allow immediate shutdown in case of an emergency. Before starting, check all parts are securely fastened and ensure no parts, such as safety guards, are damaged, improperly installed, or missing. Do not use the machine with damaged or missing parts and ensure repair or replacement is done at an authorized HERON® service center.