Product description:
Frequently Asked Questions
How to connect the power cable?
Connect the provided Schutzkontakt power cable to the power connector (21) on the function generator. Ensure a secure connection. Then connect the power cable to a Schutzkontakt socket with earth connection.
How to turn the generator on or off?
Press the power switch (19) to turn the generator on or off. When pressed, the device is powered on. After turning it on, a self-test runs, indicated by all display segments lighting up. Once the test is complete, the generator is ready for use.
What is the basic setup for the generator?
To ensure the output signal is both symmetrical and unaffected by the sweep generator, follow these settings: press the SWEEP WIDTH switch (15), press the SYM switch (14), press the DC-Offset (11), leave the ATT switch (8) unpressed, and leave the COUNTER INT/EXT switch (17) unpressed.
How to adjust the frequency range?
Use the switch in the FREQUENCY RANGE (Hz) field (13) to multiply the value of the variable frequency setting (via the FREQUENCY knob (18)). In the middle position, the factor is approximately 1. When the knob is set to MAX, the factor is slightly over 2 (MIN = 0.01). Choose a smaller frequency range for more precise adjustments in the upper control range.
What is the output impedance of the generator?
The output impedance of the generator is 50 Ohms. However, the output level is highly load-dependent. To achieve a more constant output voltage, connect the output to a 50 Ohm load resistor.
What safety precautions should be taken?
Avoid touching live parts, especially when working with voltages above 25 V AC or 35 V DC. Ensure all BNC connectors are checked for damage or short circuits before each measurement. Do not connect the input/output (BNC) directly to the power supply, chassis, or circuits without isolation transformers.
What is the maximum input voltage for the VCF and frequency counter?
The maximum input voltage for the VCF input (5) is 10 V DC/AC peak-to-peak. Ensure you do not exceed these limits to avoid damaging the generator or causing a short circuit.
What should be done if the device shows visible damage?
If the device shows visible damage, it is no longer safe to use. Stop the operation immediately and secure the device against unintended use. This is especially important if the device has been stored under unfavorable conditions or after heavy transport.
What is the purpose of the low-pass filter in the frequency counter?
The low-pass filter (LPF) is used in the frequency counter mode for measurements in the low-frequency range. It helps to filter out high-frequency noise and ensures more accurate readings when measuring signals in the audio frequency range.