What is the maximum recommended air pressure for operation?
The maximum recommended air pressure during operation must not exceed 90 psi (6.3bar). Higher air pressure may create unsafe operating conditions for the tool and the user.
How should the air supply be prepared before use?
The compressed air should be cooled and have a water filter installed at the outlet end of the compressor. Even with a water filter installed, some water may still condense in the piping or hose and will enter the tool mechanism causing premature damage to the tool.
What is the recommended diameter for the inlet pipe?
The diameter ΦA required for the inlet pipe is recommended on the specification table. The diameter ΦB required for the branch pipe should be 2 times as large as ΦA. The diameter ΦC required for the primary air supply should be 3 times as large as ΦA.
What safety precautions should be taken when operating the tool?
Always wear gloves to reduce the risk of cuts or burns. Make sure that all the specifications of the shank stone to be used are compatible with this tool. Do not use cutting wheels on this tool. Inspect the shank stone carefully before use. Use of chipped, cracked or otherwise defective implements will create an unsafe condition.
What should be done before replacing the grinding shank stone?
Always turn off the air supply and disconnect the air hose before replacing grinding shank stone or making adjustments on the tool. Ensure that the work piece is properly supported or fixed before operating. Make sure that there is no bystander in the vicinity of the working area.
How should the tool be maintained regularly?
Maintain this tool regularly by performing the same oiling application every 3 to 4 hours of operation. Do not lubricate tools with flammable or volatile liquids. Use only the lubricant recommended by Mighty-Seven or authorized dealers. Any other lubricant will lead to reduce performance of the tool and permanent damage.
What is the recommended procedure for replacing the shank stone?
Use the supplied spanners to replace. Note: Turn counterclockwise to open and replace. Ensure that the shank stone is correctly mounted and tightened before use. Then, run the tool at no-load for 30 seconds in a safe location to check the function and rotating direction.
What are the safety requirements for operating the tool?
Wearing eye/face protection can reduce the danger of high-speed materials being emitted from the tool. High sound levels may cause hearing damage. Always wear hearing protection when operating this tool. Make sure that the direction of the sparks generated from the grinding shank stone is properly directed so as not to create a hazard.
What should be done if the compressed air hose breaks unexpectedly?
Beware if the compressed air hose breaks unexpectedly, or is being connected or disconnected improperly. This whipping action may cause injury. Release the throttle lever to avoid danger if there is a failure of energy supply and when connecting or disconnecting the air hose.
What is the recommended procedure for cleaning the air hose before use?
Clean the hose with a blast of compressed air before connecting the hose to the air tool. This will prevent both moisture and dust inside the hose from entering the tool and causing possible rust or malfunction.
Related products from Mighty Seven
QP-215
User manual 60 pages
QP-327
User manual 60 pages
QP-317
User manual 60 pages
QP-123
User manual 60 pages
QB-52502
User manual 61 pages
QB-53902
User manual 61 pages
QB-52602
User manual 61 pages
QB-53802
User manual 61 pages
QB-321
User manual 63 pages
QB-313
User manual 63 pages
QB-322
User manual 63 pages
QB-324
User manual 63 pages
QB-311
User manual 63 pages
QB-312
User manual 63 pages
QC-213
User manual 65 pages
QA-111
User manual 65 pages
QA-315
User manual 65 pages
QA-421
User manual 65 pages
QA-432
User manual 65 pages
QA-611
User manual 65 pages