Product description:
Frequently Asked Questions
How do I install the stove?
The stove arrives ready for installation and must be connected to the chimney using a flue pipe. The connection between the stove and chimney should be made in a straight section with as few bends as possible, and at least horizontally, preferably rising from the stove towards the chimney. All joints must be tight. Ensure there is room for cleaning the pipe (e.g., a cleaning plug on the pipe).
What are the requirements for the floor?
The floor must be able to support the weight of the stove and any chimney together. The area in front and on both sides of the firing opening must be covered with a non-combustible floor covering. In Denmark, this non-combustible covering must extend 150 mm on each side and 300 mm in front of the firing opening. If a grooved floor panel is used, feet must be installed. Refer to sections 8.3 and 8.4 for more details.
How do I install the stove with a rear outlet?
Remove the panels on the back of the stove completely to the firebox so that there is free passage for the flue pipe. Then remove the panel attached to the firebox. The universal stud mounted on top of the stove is unscrewed and mounted on the back of the stove. The panel previously mounted on the back is now mounted on top of the stove. The flue pipe is now ready for installation.
What are the requirements for the chimney?
The chimney must be tall enough to ensure proper draft and prevent smoke from disturbing neighbors. A good draft in the chimney is essential for the stove to function as intended and burn as environmentally friendly as possible. All connections and joints must be tight, and the chimney must provide a draft of at least 1.2 mm water column, which equals 12 Pa. It is possible to connect the stove to chimneys used for other purposes, but the specific conditions must be assessed by the installer and/or chimney sweep.
How do I install an external combustion air supply?
External combustion air supply is established by drawing combustion air through an external channel directly into the stove's external combustion air inlet. External combustion air kits are available for Termatech stoves. Consult your dealer for advice. Alternatively, additional air can be supplied to the room via an air vent in the room's exterior wall or windows. Air vents supplying necessary combustion air must remain unobstructed. If there is insufficient air for combustion, the stove may produce excessive soot, damage the chimney, and pollute the environment and neighbors. Ventilation systems and boilers can create negative pressure, causing flue gases to flow back into the house, which can be dangerous (carbon monoxide poisoning). Refer to section 8.9 for information on installing an external combustion air supply.
What type of wood should I use for burning?
Only dry and clean wood should be used for burning in the stove. Suitable wood types include birch, beech, oak, ash, elm, coniferous trees, and fruit trees. The moisture content should be between 12% and 20%. The maximum size of the logs should not exceed the width of the firebox minus 4 cm (see firebox width in section 10), as otherwise they will be too close to the sides of the stove, leading to poor ventilation, sooting, and damage to the insulation plates. Wet wood is difficult to ignite, causes excessive condensation, soots the glass, and reduces energy efficiency, as water must first evaporate. Additionally, it can cause damage to the stove and chimney in the form of soot deposits and tar coatings. This can, in the worst case, lead to chimney fires. Dry wood burns too quickly, releasing gases faster than they can be burned, resulting in some unburned gases escaping through the chimney. This also reduces efficiency and harms the environment.
Can I burn waste products in the stove?
Burning waste products such as plastics, treated wood, particle board, colored brochures, glitter paper, or other impregnated materials is prohibited, as these materials are highly harmful to the environment and release toxic substances such as hydrochloric acid, dioxins, and heavy metals, causing significant harm to humans, animals, the stove, chimney, and the environment. The warranty/reclamation rights for the product will be void if these materials are burned in the stove.
What is the recommended method for lighting and continuous burning?
The instructions described here from point 1 to 6 are the same as those used when the stove was tested and approved by the Danish Technological Institute in Aarhus (TI). The fuel used was pieces of birch wood. To protect the environment and ensure you get the best performance from your new Termatech stove, it is recommended to follow these instructions.
What is the maximum load of wood allowed in the stove?
You must not place wood on top of the tertiary holes in the backmost vermiculite/insulation plates, corresponding to approximately 16 cm from the bottom plate of the firebox. Refer to section 10 for more details.
What is the purpose of the grate in the firebox?
The grate at the bottom of the firebox ensures good and easy ignition, as air can pass up through it. Ash falls down through the grate into the ash pan. When the ash pan needs to be emptied, the grate can be removed, and the remaining ash can be pushed into the pan, after which the ash pan can be emptied.
Related products from TermaTech
TT20R
User manual 68 pages
TT20R
User manual 68 pages
TT20R
User manual 136 pages
TT20R
User manual 64 pages
TT22S
User manual 60 pages
TT22S
User manual 64 pages
TT22HS
User manual 60 pages
TT22HS
User manual 64 pages
TT22RP
User manual 60 pages
TT22H
User manual 64 pages
TT22H
User manual 60 pages
TT22R
User manual 60 pages
TT22R
User manual 64 pages
TT22
User manual 60 pages
TT22
User manual 64 pages
TT22HST
User manual 60 pages
TT22HST
User manual 64 pages
TT20 Series
User manual 64 pages
TT20 Series
User manual 68 pages
TT20 Series
User manual 68 pages