Log in


or


google Continue with Google

Already have an account?

Galletti UTN 22 (12 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Galletti UTN 22 is a compact fan coil unit designed for heating applications in residential and commercial settings. It operates with a high-efficiency heat exchanger that facilitates effective heat transfer through forced air circulation. The unit features adjustable fan speeds for precise control of airflow and temperature distribution, along with a built-in thermostat for maintaining desired settings. Key specifications include a nominal heating capacity suitable for medium-sized rooms, typically up to 2.2 kW, depending on configuration. Constructed with durable, corrosion-resistant materials, it ensures reliable performance and longevity. The design incorporates a removable air filter for easy cleaning, promoting better indoor air quality. This model is versatile for wall or ceiling mounting, making it a practical choice for integrated HVAC systems. Weighing approximately 15 kg, it is energy-efficient and compatible with various heating sources, such as hot water circuits.

Frequently Asked Questions

What is the nominal heating capacity of the Galletti UTN 22?

The Galletti UTN 22 provides a nominal heating capacity of around 2.2 kW in typical configurations. Actual output depends on water inlet temperature, flow rate and room insulation, so capacity suits medium-sized rooms when installed in an appropriate hydronic circuit.

How does the UTN 22 generate and distribute heat?

The unit uses a high-efficiency water-to-air heat exchanger combined with a forced-air fan to transfer heat into the room. Adjustable fan speeds distribute warmed air evenly, while the built-in thermostat controls run time to maintain the selected temperature efficiently.

Can the UTN 22 be mounted on the wall or ceiling?

Yes, the UTN 22 is designed for flexible installation on either walls or ceilings. Consider clearance for airflow and filter access, ensure secure fixing for the unit's approximate 15 kg weight, and allow space for pipe and electrical connections.

Which heat sources are compatible with the UTN 22?

The unit is compatible with standard hot water circuits and common hydronic heating sources such as boilers or heat exchangers. It performs best with appropriately sized supply temperatures and stable flow rates to achieve the specified heating output.

How do I clean and maintain the removable air filter?

Remove the filter periodically to vacuum or wash it with mild detergent, then dry it completely before reinstalling. Cleaning frequency depends on air quality, typically every one to three months, and regular maintenance helps preserve airflow and indoor air quality.

What fan speed and thermostat controls does the UTN 22 offer?

The UTN 22 features multiple adjustable fan speeds and an integrated thermostat for precise temperature control. Lower fan settings reduce noise and energy use, while higher speeds improve heat distribution in larger or colder spaces.

Is the UTN 22 energy efficient for residential use?

Yes, the unit is designed with an efficient heat exchanger and variable fan control to minimize energy use. Proper system sizing, correct water temperatures and sensible thermostat settings further improve seasonal efficiency and operating costs.

What materials are used and how resistant is the unit to corrosion?

The UTN 22 is built from durable, corrosion-resistant materials selected for longevity in heating applications. These materials reduce the risk of degradation in typical indoor environments, though periodic inspections are recommended in more humid or aggressive atmospheres.

How loud is the Galletti UTN 22 during operation?

The unit is engineered for low operational noise, particularly at lower fan speeds suitable for living and office spaces. Actual sound level varies with selected fan speed and mounting conditions; lower speeds are recommended where quiet operation is important.

What installation and safety considerations should I be aware of?

Ensure secure mechanical mounting, adequate airflow clearance, correct hot-water connections and appropriate electrical supply for fan and controls. Follow general safety practices for pressure and temperature systems and consider professional installation to ensure reliable, compliant operation.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.