Mohlenhoff WLK 320 (100 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum operating temperature for the system convectors?
The maximum operating temperature for the system convectors is 105°C. This ensures safe and efficient operation under standard conditions.
What are the dimensions of the system convectors?
The system convectors come in widths of 180 mm, 260 mm, 320 mm, and 410 mm. The height is either 140 mm or 190 mm, and the length ranges from 1000 mm to 5000 mm.
What is the purpose of the system convectors?
System convectors are designed for use in floor areas to provide cold air shielding in front of window facades or as full heating solutions, depending on the selected supply temperature.
What are the installation requirements for the system convectors?
Installation must be carried out by qualified professionals who are responsible for proper installation and initial commissioning. The system must be installed horizontally in floor areas, and special precautions are required if used in areas with hot screed.
How many adjustment blocks are needed for a specific convector length?
The number of adjustment blocks required depends on the convector length. For example, a 1000 mm convector requires 6 blocks for a load capacity of 130 kg/m, while a 5000 mm convector requires 14 blocks for the same load capacity.
What is the function of the primary air inlet?
The primary air inlet is where external air, such as from a ventilation system, is introduced. This air is mixed with room air and heated in the heating element, creating a warm barrier in front of the window to protect against cold air.
What are the safety warnings for the system convectors?
The system convectors carry warnings about electrical hazards, potential burns, and permanent damage to the device. These warnings emphasize the importance of following safety guidelines to prevent injury or equipment damage.
What is the recommended load capacity for different adjustment block configurations?
The load capacity varies depending on the type and number of adjustment blocks used. For example, using JBA blocks with a maximum distance of 500 mm allows a load capacity of up to 130 kg/m, while using JBI blocks with a maximum distance of 1180 mm allows a load capacity of up to 205 kg/m.
What are the technical specifications for the system convectors?
The system convectors operate with a maximum working pressure of 1000 kPa (10 bar) or optionally 1600 kPa (16 bar). They use water or a water/glycol mixture (max. 30%) as the operating medium. The system is designed for horizontal installation in floor areas.
What is the purpose of the adjustment blocks?
Adjustment blocks are used for leveling and to ensure walkability. They allow the system convectors to be installed at the correct height and provide a stable base for safe operation, especially in areas with no full underlay.