Tylo SENSE COMBI (91 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the minimum volume for the sauna?
The minimum volume for the sauna should not be exceeded. Refer to Table 1 in the manual for the recommended volume based on the sauna heater's power output.
How should the sauna heater be installed?
The sauna heater should be installed on the same wall as the door, at a safe distance from the floor, walls, and interior fittings. Ensure the minimum distances specified in the manual are followed.
What is the correct placement for the sensor?
The sensor should be placed 200 mm from the heater, 40 mm from the ceiling, and at a minimum distance of 1030 mm from the ceiling. Ensure it is installed on the heater's centerline if the wall is made of heat-absorbing material.
What are the requirements for the sauna room insulation?
The sauna room must meet insulation requirements as specified in the manual. Poor insulation can increase the risk of fire and affect the heater's performance.
How should the ventilation system be set up?
The ventilation system must be installed according to the instructions in the manual. Ensure the intake and exhaust vents are placed correctly to maintain proper air circulation and prevent overheating.
What type of cable is required for the sauna heater?
Use a cable rated for the heater's power output, with the correct cross-sectional area. The cable should be routed outside the insulation and properly secured according to the installation diagram.
What safety precautions should be taken during installation?
Always ensure the heater is connected to the correct voltage and phase. Use a qualified electrician for electrical connections. Avoid placing the heater near flammable materials and ensure proper ventilation.
How should the control panel be installed?
The control panel should be mounted at a safe distance from the heater and placed high on the wall or in the ceiling. Ensure it is securely fastened and positioned so it aligns with the door and intake vent.
What is the recommended distance between the heater and the wall?
The minimum distance between the heater and the wall should be at least 110 mm. Ensure there is also a minimum distance of 100 mm from interior fittings and 20 mm from the ceiling.
How should the control panel be connected to the heater?
The control panel should be connected using a 2-LIFYCY 2X2X0.2 mm² twisted pair cable. Follow the wiring diagram in the manual to ensure correct connections and avoid electrical faults.