Log in


or


google Continue with Google

Already have an account?

Dräger PSS Serie (2 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Dräger PSS Series is a range of respiratory protection devices designed for use in hazardous environments. These devices provide a reliable source of breathable air, ensuring the safety of the user during operations in areas with contaminated air. The PSS Series is known for its robust construction and efficient air supply, making it suitable for a variety of industrial and emergency applications. It is equipped with a high-performance air delivery system and is easy to maintain, ensuring long-term operational reliability.

Frequently Asked Questions

What type of respiratory protection does the Dräger PSS Series provide?

The Dräger PSS Series provides self-contained breathing apparatus (SCBA) protection that supplies breathable air independent of the ambient atmosphere. It is typically a positive-pressure system designed for firefighting and industrial rescue, ensuring respiratory safety in immediately dangerous-to-life-or-health environments.

How does the PSS Series breathing apparatus work in hazardous environments?

The PSS Series supplies air from a compressed-air cylinder through a pressure reducer and demand valve to a full-facepiece, maintaining positive pressure inside the mask. Integrated alarms and gauges warn the user of low air, while the regulator controls flow for safe, continuous breathing under stress.

What are the main components of a PSS Series SCBA unit?

A typical PSS unit consists of a high-pressure cylinder, pressure reducer/regulator, full-face mask or facepiece, harness and backplate, pressure gauge and warning alarm, and connecting hoses. Each component is designed for robust field use and must be inspected and maintained regularly.

What routine maintenance is required to keep a PSS Series unit operational?

Routine maintenance includes daily visual inspections, functional checks of the demand valve and alarms, cleaning the facepiece after use, replacing consumables such as seals and straps, and scheduled servicing by authorized technicians according to manufacturer recommendations and applicable regulations.

How should I clean and disinfect the PSS Series facepiece after use?

Clean the facepiece with a mild detergent and approved disinfectant, avoiding harsh solvents that can damage seals. Gently remove and dry removable parts, inspect sealing surfaces for damage, and ensure the facepiece is fully dry before storage to prevent microbial growth and material degradation.

What pre-use checks should be performed before each shift?

Before each shift, check cylinder pressure, confirm the pressure gauge and low-air alarm function, inspect hoses and couplings for damage, verify facepiece seals and harness integrity, and conduct a positive-pressure fit and demand-valve function test. Record completion of these checks for traceability.

What operator training is needed to use the PSS Series safely?

Operators require hands-on training in donning and doffing, facepiece fit-testing, emergency procedures for low-air or malfunction, air management techniques, and routine inspections. Regular refresher courses and scenario-based drills ensure competence and safe use under operational stress.

Can the PSS Series be fitted with communication and safety accessories?

Yes, PSS units can accept certified accessories such as integrated communication systems, voice amplifiers, personal alert safety systems (PASS), and approved rescue aids. Accessory compatibility depends on the specific model and must be verified to maintain certification and safe operation.

What determines the service life of PSS Series components and how can I extend it?

Service life depends on usage, environmental exposure, and maintenance; consumables like face seals wear faster than metal components. Extend service life through proper cleaning, storage, regular inspections, timely replacement of worn parts, and adherence to manufacturer service intervals and regulatory testing requirements.

How should Dräger PSS Series units be stored and transported when not in use?

Store units in a clean, dry, temperature-stable environment protected from UV, chemicals, and mechanical damage. Secure cylinders to prevent impact during transport, follow local regulations for charged or depressurized storage, and ensure units are inspected after transport before being returned to service.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.