How to connect the ice maker to the electrical network?
Connect the ice maker only to the potable water supply. Use the new set of flexible joints (water tube) provided with the machine. The old set of joints must not be reused. Perform the water connections before the electrical ones. Attach the 3/4" supply tube to the machine and the cold potable water supply line. It is advisable to install a shut-off valve (not supplied by us) for convenience and safety.
What are the temperature requirements for the environment?
Ensure the ambient temperature does not drop below 10°C (50°F) or exceed 43°C (110°F). The water temperature should not be lower than 10°C (50°F) or higher than 32°C (90°F).
What are the water pressure requirements?
The water supply pressure should not be less than 0.1 MPa (1 bar) or exceed 0.5 MPa (5 bar). If the pressure exceeds 0.5 MPa, install a pressure reducer on the water supply line to the machine.
How to clean the air-cooled condenser?
Clean the air-cooled condenser regularly to prevent blockages. Ensure the condenser is not obstructed and is placed in a well-ventilated area. Avoid dusty environments to prevent rapid clogging of the condenser.
How to perform the washing and sanitization cycle?
The washing and sanitization cycle should be performed by a certified technician. This process involves draining the water, cleaning the internal components, and using appropriate cleaning agents to ensure hygiene and functionality.
What is the function of the RESET button?
The RESET button serves two main functions: it resets the maintenance warning and resets the start of the washing cycle. Pressing this button will initiate these processes as specified in the instructions.
How to check the water level in the tray?
The water level in the tray is maintained by a float connected to a microcontroller that controls the opening or closing of the water inlet valve. Adjust the float or sensor on the designated slot after loosening the fixing screw, ensuring the power is disconnected during adjustment.
What happens when the ice cubes reach the desired size?
Once the ice cubes reach the desired size, they come into contact with the agitating blades, causing the motor-reducer to oscillate. This action triggers a microcontroller to open an electric valve, sending hot gas to the evaporator, which gradually detaches the ice cubes from the evaporator rods.
What are the alarm signals for air/water cooled models?
Overheating of the condenser: the machine restarts automatically once the cause of the alarm is resolved. Possible causes include a clogged air filter, faulty fan, excessively high ambient temperature, or lack of water (only for water-cooled versions). Water error: the machine restarts automatically after 60 minutes if there is no water supply.
What is the function of the LED indicators?
The LED indicators show the machine's status. Green indicates the machine is on, red indicates an error, and flashing lights indicate different statuses like maintenance alerts, washing cycles, or waiting for startup. Refer to the manual for detailed descriptions of each light pattern.
Related products from Icematic
E50
User manual 72 pages
E50
User manual 72 pages
E50
User manual 40 pages
E60
User manual 40 pages
E60
User manual 72 pages
E60
User manual 72 pages
E75
User manual 40 pages
E75
User manual 72 pages
E75
User manual 72 pages
E90
User manual 40 pages
E90
User manual 72 pages
E90
User manual 72 pages
E35
User manual 72 pages
E35
User manual 72 pages
E35
User manual 40 pages
E25
User manual 40 pages
E25
User manual 72 pages
E25
User manual 72 pages
E45
User manual 40 pages
E45
User manual 72 pages