Product description:
Frequently Asked Questions
What is the maximum power rating of the TML vector drive?
The TML vector drive is available in power ratings ranging from 0.25 kW to 2.2 kW, with specific models such as ETML251X2SFA (0.25 kW), ETML371X2SFA (0.37 kW), and ETML222X2SFA (2.2 kW).
What are the input voltage and frequency specifications for the TML drive?
The input voltage for the TML drive is 230 V, with a frequency range of 50-60 Hz. The input is a three-phase configuration with neutral and protective earth (1/N/PE).
What is the output voltage and frequency range of the TML drive?
The output voltage of the TML drive ranges from 0 to 230 V, and the frequency range is 0 to 240 Hz. This allows for precise control of motor speed and torque.
What are the environmental conditions for operating the TML drive?
The TML drive operates within an ambient temperature range of 0 to +55 °C, with a derating of 2.5% per degree Celsius above +40 °C. It is suitable for installation up to 4000 meters above sea level.
What are the safety precautions when handling the TML drive?
The TML drive contains high-voltage components that can retain charge for up to 180 seconds after power is disconnected. Always wait at least three minutes before touching the drive. Ensure proper grounding and follow all safety pictographs and warnings.
What are the EMC compliance requirements for the TML drive?
The TML drive complies with EMC regulations, including EN 61000-3-2 for harmonic current limitations. Proper shielding, grounding, and cable selection are required to ensure compliance. Additional measures such as filters or active filters may be necessary for higher power applications.
What are the installation dimensions for the TML drive?
The installation dimensions vary depending on the model. For example, the ETML251X2SFA has dimensions of 93 mm (a), 84 mm (a1), 146 mm (b), 128 mm (b1), 17 mm (b2), 83 mm (c), 15 mm (s1), 50 mm (s2), and a weight of 0.5 kg.
What are the recommended cable cross-sections for the TML drive?
The recommended cable cross-sections depend on the model and application. For example, the ETML251X2SFA requires a minimum of 1.5 mm² for the main power cables, while control circuits should use wiring suitable for NEC Class 1 circuits.
What are the safety certifications for the TML drive?
The TML drive is certified to the CE marking, complying with the Low Voltage Directive (2006/95/EC) and UL 508C for power conversion equipment. These certifications ensure compliance with safety and electromagnetic compatibility standards.
What are the recommended installation practices for the TML drive?
The TML drive should be installed in a clean, dry environment with minimal vibration and temperature fluctuations. Ensure proper mechanical and electrical installation, including correct mounting, cable routing, and grounding to prevent electrical hazards and ensure reliable operation.
Related products from Lenze
l-force 9400
User manual 132 pages
EZZ0015
User manual 8 pages
EZZ0016
User manual 8 pages
ETML371X2SFA
User manual 124 pages
ETML551X2SFA
User manual 124 pages
ETML751X2SFA
User manual 124 pages
E94AZRP0294
User manual 132 pages
9350
User manual 146 pages
9350
User manual 174 pages
EMB9352-E
User manual 146 pages
EMB9352-E
User manual 174 pages
EMB9351-C
User manual 146 pages
EMB9351-E
User manual 146 pages
EMB9351-E
User manual 174 pages
EMB9352-C
User manual 146 pages
EMB9352-C
User manual 174 pages