Product description:
Frequently Asked Questions
How to connect the door station and monitor?
To connect the door station and monitor, use two wires (0.75 mm² up to 80 m or 1.5 mm² up to 120 m). Ensure the wires are properly connected according to the wiring diagram and label on the back of the monitor and door station. Follow the configuration settings for the switches on the door station and configure the monitor interface as described in the setup section.
What is the maximum distance for cable connection?
The maximum distance for cable connection is 120 meters when using 1.5 mm² cables. For shorter distances, 0.75 mm² cables can be used up to 80 meters. Ensure cables are not run in the same sheath as electrical wires to avoid interference.
How to set up the door station for multiple families?
To set up the door station for multiple families, use the switch labeled '1' on the door station. Set it to the left for one family mode or to the right for two-family mode. This allows the door station to be shared between two families, each with up to three monitors.
How to adjust the volume on the monitor?
To adjust the volume on the monitor, use a cross-shaped screwdriver to turn the volume control knob. This will allow you to set the sound level of the monitor according to your preference.
What is the IP rating of the door station?
The door station has an IP44 rating, which means it is protected against splashing water from any direction and dust ingress. This makes it suitable for outdoor use in various weather conditions.
How to install the monitor on the wall?
To install the monitor on the wall, position the wall mount so that the monitor screen is approximately 1.60 meters above the floor. Locate the mounting holes using the bracket provided, then drill the holes and secure the mount firmly.
What is the purpose of the night vision LED on the door station?
The white LED on the door station indicates night vision mode. It activates when there is low light, allowing the camera to capture clear images even in the dark. This feature enhances security by providing visibility during nighttime.
Can the door station control a gate opener?
Yes, the door station can control a gate opener. Connect the gate opener to the dry contact terminals (terminals 5 and 6) on the back of the door station. Ensure the gate opener is only activated when the corresponding door station video feed is displayed.
How to connect an electric lock or door latch?
To connect an electric lock or door latch, ensure it is equipped with a mechanical memory function. Connect the lock or latch to terminals 7 and 8 on the back of the door station. The lock or latch can only be activated when the corresponding door station video feed is displayed.
Related products from Philips
WelcomeEye Connect
User manual 112 pages
531001
User manual 112 pages
WelcomeEye Comfort
User manual 100 pages
WelcomeEye Comfort
User manual 152 pages
531029
User manual 104 pages
WelcomeHive Pro Outdoor8
User manual 104 pages
531028
User manual 104 pages
WelcomeEye Link 531034
User manual 120 pages