Product description:

The THOMSON Smart Bracket II is an intercom system component designed for easy installation and integration into existing door entry systems. It features a durable construction and a user-friendly interface, allowing for seamless communication between visitors and residents. The device supports clear audio transmission and is compatible with a range of intercom models. Its compact design makes it suitable for various installation scenarios, ensuring reliable performance in both residential and commercial environments.

Frequently Asked Questions

What is the maximum cable length for the street unit connection?

The maximum cable length for connecting the street unit to the monitor is 100 meters. For lengths between 5 to 50 meters, use 0.75mm² cable, and for 50 to 100 meters, use 1.5mm² cable.

How to connect the street unit to the door opener?

Connect the street unit to the door opener using a dry contact. The cable length should be between 0 and 25 meters. Ensure the connection is made directly to the terminals specified on the street unit description, without worrying about polarity.

What is the maximum distance for the video intercom system?

The video intercom system has a maximum distance of 25 meters for the street unit to the monitor. For extended distances, additional units or longer cables may be required, but the maximum recommended length is 100 meters.

How to adjust the volume of the street unit?

The volume of the street unit can be adjusted through the settings interface on the video monitor. This setting is accessible via the menu of your monitor's parameter management section, where you can fine-tune the volume for both the chime and conversation.

What is the function of the RFID feature in the system?

The RFID feature allows you to manage access using RFID badges even when the screen is turned off. This enables remote control of the door or gate using the badge, providing a secure and convenient way to grant access.

How to program the administrator badge?

To program the administrator badge, press the reset button on the back of the street unit for 5 seconds. This will emit 6 short beeps. Then, pass the yellow administrator badge over the RFID reader, which will confirm the programming with a short beep. Repeat the process for the blue and red badges, with the red badge requiring a long beep for confirmation.

What are the safety precautions for installation?

Avoid installing the intercom near other electronic devices like computers or TVs. Do not install it near chemical products or toxic gas sources. Ensure the unit is not exposed to direct sunlight, rain, or high humidity. Always use the provided cables and avoid splicing or extending them to prevent damage and void the warranty.

What should I do if the system is not working properly?

If the system is not functioning correctly, check the connections and ensure all cables are properly attached. If the issue persists, contact the technical support team for assistance. Always refer to the user manual for detailed troubleshooting steps and ensure the unit is correctly powered and configured.

What is the purpose of the white LEDs on the street unit?

The white LEDs on the street unit are used for night vision. They allow the system to identify visitors without additional lighting, making it easier to see in low-light conditions while maintaining security and convenience.

How to connect the additional monitor?

To connect an additional monitor, use the blue terminal on the street unit and connect it to the corresponding port on the additional monitor. Ensure the cable is properly connected and that the monitor is powered. The system will recognize the additional monitor and allow for extended use and control.