Product description:

The Zapi COMBIACX is a control unit designed for programming and adjustment via a digital console. It features technical specifications including digital inputs DI0 to DI10, available in both 24 V and 36/48 V systems. The unit also incorporates microswitches and an analog unit for additional control functions. It supports other analogue control units, providing flexibility in system configuration.

Frequently Asked Questions

What is the maximum current for the inverter at 24V?

The inverter's maximum current at 24V is 165A (RMS) for 2 minutes, with a continuous output current of 70A (RMS).

What voltage options are supported by the COMBIACX and ACEX inverters?

The COMBIACX and ACEX inverters support voltage options of 24V, 36V, and 48V, providing flexibility for various applications.

How does the controller handle regenerative braking?

The controller supports regenerative braking functions, which help in energy recovery during deceleration, improving overall efficiency.

What is the operating frequency of the inverter?

The inverter operates at a frequency of 8kHz, ensuring efficient and smooth motor performance under varying loads.

What is the switching threshold for DI0 to DI10 in the 24V system?

The switching threshold for DI0 to DI10 in the 24V system is 4V with a tolerance of ±0.5V, ensuring reliable signal detection.

What is the input impedance for DI0 to DI10 in the 36/48V system?

The input impedance for DI0 to DI10 in the 36/48V system is 13.5kOhm with a tolerance of ±1kOhm, providing stable signal handling.

What are the recommended specifications for microswitches?

Microswitches should have contact resistance below 0.1Ohm and leakage current below 100µA to ensure reliable operation and minimal interference.

How is the analog input connected to the accelerator unit?

The analog input can be connected to an accelerator unit using a 3-wire configuration, with the potentiometer supplied through CNC#8 and its output signal input to CPOT1 (CNC#4) within a 0 to 10V range.

What is the recommended load range for the potentiometer?

The potentiometer value should be in the 0.5 to 10 kOhm range, with a load current between 1.5mA and 30mA to avoid faults and ensure proper operation.

What is the function of the CANbus interface?

The CANbus interface allows for communication with other devices and systems, enabling advanced control and diagnostics in industrial applications.