Product description:
Frequently Asked Questions
How do I turn on the laser?
To turn on the laser, press the power button. The laser will start in automatic self-leveling mode, and the LEDs will remain on for 2 seconds. The laser is level when the leveling indicator stops flashing.
What happens if the laser is out of self-leveling range?
If the laser is positioned beyond its self-leveling range of ±8%, the laser beam and indicators will flash simultaneously. Turn the unit off, reposition it within the self-leveling range, and turn it back on. If it remains out of range for more than 10 minutes, the unit will shut down completely.
How do I activate standby mode?
To activate standby mode, press and hold the remote control's manual button for 3 seconds. The laser beam, rotor, self-leveling system, and LEDs will shut down, but the HI alert remains active. The battery LED will flash every 4 seconds to indicate standby mode.
How do I use manual mode?
In horizontal mode, pressing the manual button on the remote control switches the laser to manual mode, indicated by the flashing red LED. In manual mode, you can slope the Y-axis using the up/down arrows and the X-axis using the left/right arrows. Press the manual button again to return to automatic self-leveling mode.
How do I determine the height of instrument (HI)?
The height of instrument (HI) is the elevation of the laser beam. To determine HI, add the grade rod reading to a benchmark or known elevation. Set up the laser and place the grade rod on a benchmark, slide the receiver up/down until it shows an on-grade reading, then add the rod reading to the benchmark to calculate the HI.
How do I use the Y-axis single slope mode?
To activate the Y-axis single slope mode, press the manual button on the remote control twice. This will toggle the laser to manual mode and the Y-axis single slope mode, indicated by the flashing red and green LEDs. In this mode, you can slope the Y-axis using the up/down arrows while the X-axis remains in automatic self-leveling mode.
How do I check the calibration of the Y- and X-axes?
To check the calibration of the Y- and X-axes, set up the laser 30 meters from a wall and allow it to level. Raise/lower the receiver until it shows an on-grade reading for the +Y axis, then mark the wall. Rotate the laser 180° and repeat for the -Y axis. Measure the difference between the marks. If they differ by more than 6 mm at 30 meters, the laser needs calibration.
What is the laser's self-leveling range?
The laser's self-leveling range is approximately ±5°. If the laser is positioned beyond this range, the laser beam and indicators will flash simultaneously. Turn the unit off, reposition it within the self-leveling range, and turn it back on.
What is the battery life of the laser?
The laser uses 2 x 1.5V alkaline D-cell batteries. Alkaline batteries provide approximately 80 hours of operation, while NiMH batteries provide about 35 hours. The unit is water-resistant and can be used indoors and outdoors.
What are the technical specifications of the laser?
The laser has a leveling accuracy of ±3 mm/30 m, a rotation speed of approximately 600 rpm, and an operational area of up to 350 meters in diameter. It uses a red diode laser (650 nm) and is class 2 (<3mW). The laser is water and dust-resistant (IP54) and operates within a temperature range of -20°C to 70°C.