Product description:
Frequently Asked Questions
How to align the sender and receiver for WSE16?
To align the sender and receiver for WSE16, position the sender so that the emitted light beam (red for WSO16P or infrared for WSO16I) hits the receiver. Ensure there are no objects blocking the beam path and that the optical openings of the sensors are completely clear. Use white paper or a reflector as an alignment aid for better visibility.
What is the maximum tightening torque for the sensor?
The maximum permissible tightening torque for the sensor is less than 1.3 Nm. Ensure that the sensor is tightened within this limit to avoid damage or misalignment.
What are the electrical connection requirements for WSE16?
The sensors must be connected in a voltage-free state. Use the correct wire colors and pin assignments as specified in the connection diagrams. Ensure that all electrical connections are established before applying power to the system.
How to adjust the light/dark switching function?
The light/dark switching function can be adjusted using the Teach pushbutton. This allows you to set the threshold at which the sensor switches between detecting light and dark conditions, ensuring accurate object detection based on your application requirements.
What is the purpose of the Alarm output?
The Alarm output provides a pre-failure notification if the sensor is only partially operational. It flashes when the sensor is contaminated or misaligned. In a good state, the output is LOW (0), and it becomes HIGH (1) if the sensor is excessively contaminated.
How to test the sensor's functionality?
To test the sensor's functionality, use the Test input to simulate the absence of an object between the sender and receiver. This will shut down the send LED or simulate object detection. Refer to the test table to verify the sensor's response and ensure it behaves as expected.
What is the Health output used for?
The Health output provides a pre-failure notification if the sensor is partially operational or if the cable is interrupted. It flashes in such cases. In a good state, the output is HIGH (1), and it becomes LOW (0) if the sensor is excessively contaminated or the cable is interrupted.
How to handle multiple through-beam sensors?
When using multiple through-beam sensors, swap the sender and receiver arrangement at every second sensor and ensure sufficient distance between them. This prevents mutual interference and ensures accurate detection across the entire system.
What is the operating reserve for WSE16?
The operating reserve for WSE16 refers to the additional distance beyond the sensing range that the sensor can reliably detect objects. It can be adjusted to reduce the risk of switching errors, especially in applications with reflections or other interference.
How to perform a teach-in for the sensor?
A teach-in can be performed via IO-Link or using the Teach-in button on the housing. This allows the sensor to suppress switching errors by adjusting its sensitivity settings, which is particularly useful in applications with reflections or other interference.
Related products from SICK
W9-3
User manual 144 pages
W9-3
User manual 54 pages
LFP Inox
User manual 56 pages
LFP Inox
User manual 116 pages
WTB4-3P2100S13
User manual 38 pages
WL12G-3P3572S12
User manual 48 pages
WLA12L
User manual 212 pages
WE34
User manual 164 pages
WS34
User manual 131 pages
WS34
User manual 164 pages
WTF12L
User manual 232 pages
WTF12V
User manual 232 pages
OLS20
User manual 4 pages
PowerProx - WTT12L
User manual 70 pages
PowerProx - WTT12L
User manual 93 pages
PowerProx - WTT12L
User manual 140 pages
PowerProx - WTT12L
User manual 164 pages
RAY10
User manual 144 pages
RAY10
User manual 166 pages
RAY10
User manual 184 pages