Product description:

The ARRI D 25 is a professional 2.5 kW HMI spotlight designed for film and television lighting applications. It produces a color temperature of 5600K, delivering daylight-balanced illumination with high efficiency. The fixture features a focusable lens system, allowing users to adjust the beam from a narrow spot to a wide flood for precise control over light spread. Constructed with durable materials, it ensures reliability in demanding production environments. Key attributes include a high-reflectance mirror for optimized light output and compatibility with various accessories for beam shaping and diffusion. This spotlight is engineered for consistent performance in studio and location settings.

Frequently Asked Questions

What power and ballast does the ARRI D 25 require?

The ARRI D 25 is a 2.5 kW HMI fixture and requires a ballast specifically rated for a 2.5 kW HMI lamp and the local mains voltage. Use a ballast with proper ignition capability and matching lamp ratings; using the correct ballast ensures reliable ignition, stable output and protects the lamp and fixture from electrical stress.

How do I adjust the beam from a narrow spot to a wide flood?

Beam shaping is achieved with the fixture’s focusable lens system: operate the focus control to move the lens and mirror assembly, which narrows or widens the beam. For finer control, combine focus adjustment with barn doors, scrims or diffusers to tailor edge quality and spill for the scene.

What safety precautions are necessary when using the ARRI D 25?

Treat the ARRI D 25 as a high-energy discharge light: allow full cooldown before servicing, avoid direct eye exposure to the arc, secure the fixture with a safety cable, and ensure proper ventilation. Never run the lamp without its protective front glass or UV filter to prevent harmful ultraviolet exposure.

How should I maintain and clean the ARRI D 25 for consistent performance?

Regular maintenance includes cleaning the lens and high-reflectance mirror with a lint-free cloth and approved cleaning fluid, checking cable integrity and connectors, and ensuring vents are clear. Routine inspections and gentle cleaning preserve light output and prevent overheating or premature lamp failure.

Which accessories can I use with the ARRI D 25 for shaping and diffusion?

The D 25 is compatible with barn doors, gel frames, diffusion domes, chimera softboxes, scrims, snoots and honeycomb grids for directional control. Choose accessories rated for the fixture’s heat and size to avoid damage and to maintain consistent beam quality on set.

What is the color temperature of the ARRI D 25 and how do I match it?

The ARRI D 25 produces a daylight-balanced 5600 K output, ideal for outdoor and daylight-matched setups. When mixing with tungsten fixtures, use CTO conversion gels or camera white-balance adjustments to maintain consistent color across the scene.

How often should I replace the HMI lamp and what are end-of-life signs?

Replace the HMI lamp proactively once you notice color shift toward green/blue, reduced output, longer ignition time or visible blackening of the bulb. Lamp lifespan varies by usage and operating conditions, so keep spares and monitor performance for consistent color and intensity.

Can I dim the ARRI D 25 directly from a lighting console or mains dimmer?

You should not dim the ARRI D 25 directly from a mains dimmer. HMI fixtures require a compatible ballast with a dedicated dimming function or a mechanical shutter. Using incorrect dimming methods can damage the lamp and ballast and produce unstable light output.

How should I mount the ARRI D 25 on a stand or truss safely?

Mount the D 25 using a properly rated yoke, clamp or spigot and always attach a certified safety cable. Verify the stand or truss load capacity, lock the fixture securely, and consider the center of gravity and cable routing to prevent tipping and ensure safe operation.

What troubleshooting steps should I take if the ARRI D 25 fails to ignite?

First check the ballast connection, power source and lamp seating. Confirm ballast status indicators and allow cooling time before retrying ignition. If the lamp still fails to ignite, inspect lamp condition and connectors and consult qualified service personnel to avoid repeated ignition attempts that could damage components.