Product description:

The Beha-Amprobe AT-6000-EUR is a high-precision measuring instrument designed for accurate electrical measurements. It features a digital display for clear readings and is suitable for a wide range of applications in electrical engineering and maintenance. The device supports multiple measurement functions, including voltage, current, and resistance. It is built with durable materials to ensure reliability in demanding environments. The AT-6000-EUR is equipped with a user-friendly interface and offers fast response times for efficient use in professional settings.

Frequently Asked Questions

How do I trace energized wires?

To trace energized wires, connect the green and red test leads to the transmitter, plug the socket adapter into the receptacle, and connect the red lead to the energized hot wire. The signal will only be transmitted between the load-side and the source of power. Use the receiver in Quick Scan Mode to locate the signal.

How do I trace de-energized wires?

To trace de-energized wires, connect the green and red test leads to the transmitter, plug the socket adapter into the receptacle, and connect the red lead to the de-energized hot wire. The signal will only be transmitted between the load-side and the source of power. Use the receiver in Quick Scan Mode to locate the signal.

How do I use Precision Tracing Mode?

To use Precision Tracing Mode, turn on the transmitter, verify the test leads are properly connected, and select HIGH signal mode by pressing HI. Turn on the receiver, press the MODE button until Precision Tracing is selected, and scan the target area with the tip sensor to find the highest signal level. Adjust sensitivity as needed to keep the signal strength near 50.

How do I identify breakers and fuses?

To identify breakers and fuses, connect the green and red test leads to the transmitter, verify the test leads are properly connected, and select HIGH signal mode by pressing HI. Turn on the receiver, press the MODE button until Breaker Locating mode is selected, and align the tip sensor groove with the breaker. Scan all breakers to locate the one with the highest signal.

How do I verify if a wire is energized?

To verify if a wire is energized, turn on the receiver and press the MODE button until the Non-Contact Voltage (NCV) function is selected. Hold the receiver with the tip sensor against the wire. For precise pinpointing, increase or decrease sensitivity by pressing + or - on the keypad.

How do I trace shorts in a cable?

To trace shorts in a cable, connect the transmitter with the test leads to the circuit, hold down the HIGH button for two seconds to activate Loop mode, and start tracing the cable until the signal stops. Move the transmitter to the other end of the wire and repeat tracing from the opposite end. If the signal stops at the same location, the fault has been located.

How do I trace breaks in a cable?

To trace breaks in a cable, ensure the wire is de-energized, connect the transmitter with the test leads to the circuit, and select HIGH signal mode by pressing HI. Turn on the receiver, press the MODE button until Precision Tracing is selected, and start tracing the cable until the signal stops. Move the transmitter to the other end of the wire and repeat tracing from the opposite end. If the signal stops at the same location, the fault has been located.

How do I trace wires in metal conduit?

To trace wires in metal conduit, connect the green and red test leads to the transmitter, plug the socket adapter into the receptacle, and connect the red lead to the energized hot wire. The signal will only be transmitted between the load-side and the source of power. Open junction boxes and use the receiver tip sensor to detect which wire is carrying the signal. Move from junction box to junction box to follow the path of the wire.

What are the specifications of the AT-6000-RE receiver?

The AT-6000-RE receiver has an LCD display measuring 6.35 cm (2.5 in), with dimensions 36.72 x 48.96 mm (1.45 x 1.93 in) and a resolution of 240 x 320 pixels (RGB). It uses a TFT-LCD display with 262 K colors. The operating temperature ranges from -20 °C to 50 °C (-4 °F to 122 °F), and the operating humidity is 45% to 95% RH.

What is included in the AT-6020-EUR kit?

The AT-6020-EUR kit includes an AT-6000-RE receiver, an AT-6000-TE transmitter, a TL-6000-EUR test lead and accessory kit, an ADPTR-SCT-EUR socket-check adapter, a CT-400-EUR signal clamp (optional), a CC-6000 hard carrying case, a user manual, 12 - 1.5 V AA (IEC R6) batteries, 12 rechargeable batteries, and 3 battery chargers.